Enhancing quality in Diffusion Tensor Imaging with anisotropic anomalous diffusion filter

نویسندگان

  • Carlos Ernesto Garrido Salmon
  • Antonio Carlos dos Santos
  • Luiz Otávio Murta Junior
چکیده

Introduction: Diffusion tensor imaging (DTI) is an important medical imaging modality that has been useful to the study of microstructural changes in neurological diseases. However, the image noise level is a major practical limitation, in which one simple solution could be the average signal from a sequential acquisition. Nevertheless, this approach is time-consuming and is not often applied in the clinical routine. In this study, we aim to evaluate the anisotropic anomalous diffusion (AAD) filter in order to improve the general image quality of DTI. Methods: A group of 20 healthy subjects with DTI data acquired (3T MR scanner) with different numbers of averages (N=1,2,4,6,8, and 16), where they were submitted to 2-D AAD and conventional anisotropic diffusion filters. The Relative Mean Error (RME), Structural Similarity Index (SSIM), Coefficient of Variation (CV) and tractography reconstruction were evaluated on Fractional Anisotropy (FA) and Apparent Diffusion Coefficient (ADC) maps. Results: The results point to an improvement of up to 30% of CV, RME, and SSIM for the AAD filter, while up to 14% was found for the conventional AD filter (p<0.05). The tractography revealed a better estimative in fiber counting, where the AAD filter resulted in less FA variability. Furthermore, the AAD filter showed a quality improvement similar to a higher average approach, i.e. achieving an image quality equivalent to what was seen in two additional acquisitions. Conclusions: In general, the AAD filter showed robustness in noise attenuation and global image quality improvement even in DTI images with high noise level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anisotropic Anomalous Filter as a Tool for Decreasing Patient Exam Time in Diffusion Weighted Mri Protocols

Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) are noisy submodalities images in magnetic resonance imaging (MRI) and usually have long acquisition time due to repetitions needed to improve the signal noise ratio (SNR). Here we propose and evaluate anisotropic anomalous diffusion (AAD) filter on DTI and DWI to enhance SNR and reduce the need for repetitions. Anisotropic ano...

متن کامل

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

Anisotropic fractional diffusion tensor imaging.

Traditional diffusion tensor imaging (DTI) maps brain structure by fitting a diffusion model to the magnitude of the electrical signal acquired in magnetic resonance imaging (MRI). Fractional DTI employs anomalous diffusion models to obtain a better fit to real MRI data, which can exhibit anomalous diffusion in both time and space. In this paper, we describe the challenge of developing and empl...

متن کامل

Scatterer Density in Edge and Coherence Enhancing Nonlinear Anisotropic Diffusion for Medical Ultrasound Speckle Reduction

This paper proposes new enhancement models to the methods of nonlinear anisotropic diffusion to greatly reduce speckle and preserve image features in medical ultrasound images. By incorporating local physical characteristics of the image, in this case scatterer density, in addition to the gradient, into existing tensorbased image diffusion methods, we were able to greatly improve the performanc...

متن کامل

Anisotropic anomalous diffusion assessed in the human brain by scalar invariant indices.

A new method to investigate anomalous diffusion in human brain, inspired by the stretched-exponential model proposed by Hall and Barrick, is proposed here, together with a discussion about its potential application to cerebral white matter characterization. Aim of the work was to show the ability of anomalous diffusion indices to characterize white matter structures, whose complexity is only pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017