Development and Validation of a Gas Chromatography Method for the Trace Level Determination of Allylamine in Sevelamer Hydrochloride and Sevelamer Carbonate Drug Substances

نویسندگان

  • Raju V. S. N. Kadiyala
  • Pavan Kumar S. R. Kothapalli
  • Madhava Reddy Peddolla
  • Pradeep Rajput
  • Hemant Kumar Sharma
  • Shankar Reddy Budeti
  • Himabindu Gandham
  • Annapurna Nowduri
چکیده

A capillary gas chromatography method using a flame ionization detector has been developed for the trace analysis of allylamine (AA) in sevelamer hydrochloride (SVH) and sevelamer carbonate (SVC) drug substances. The method utilized a mega bore capillary column DB-CAM (30 m × 0.53 mm × 1.0 μm) with a bonded and cross-linked, base-deactivated polyethylene glycol stationary phase and was validated for specificity, sensitivity, precision, linearity, and accuracy. The detection and quantitation limits obtained for allylamine were 2 μg/g and 6 μg/g, respectively. The method was found to be linear in the range between 6 μg/g and 148 μg/g with a correlation coefficient of 0.9990. The average recoveries obtained in SVH and SVC were 93.9% and 99.1%, respectively. The developed method was found to be robust for the determination of AA in sevelamer drug substances and also the specificity was demonstrated with a gas chromatograph coupled with a mass spectrometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sevelamer carbonate in the treatment of hyperphosphatemia in patients with chronic kidney disease on hemodialysis

Sevelamer carbonate is an anion exchange pharmaceutical, developed to improve on the performance of the non-absorbable, non-calcium, and metal-free phosphate binder sevelamer hydrochloride. Sevelamer carbonate is expected not to worsen metabolic acidosis, as previously reported during long-term treatment with sevelamer hydrochloride in hemodialysis (HD) patients. Carbonate is the alternate coun...

متن کامل

Determination of Residual Epichlorohydrin in Sevelamer Hydrochloride by Static Headspace Gas Chromatography with Flame Ionization Detection

A sensitive static headspace gas chromatographic method was developed and validated for the determination of residual epichlorohydrin (ECH) in sevelamer hydrochloride (SVH) drug substance. This method utilized a Phenomenex Zebron ZB-WAX GC column, helium as carrier gas with flame ionization detection. The critical experimental parameters, such as, headspace vial incubation time and incubation t...

متن کامل

DRUG EVALUATION Sevelamer carbonate in the management of hyperphosphatemia

10.2217/14750708.5.4.545 © 2 Sevelamer carbonate appears to be a promising new agent in the control of serum phosphorus levels in subjects with chronic kidney disease. It contains the same active moiety as sevelamer hydrochloride, but has carbonate instead of chloride as the counterion. This substitution has resulted in a statistically significant improvement in serum bicarbonate levels in chro...

متن کامل

A randomized, crossover design study of sevelamer carbonate powder and sevelamer hydrochloride tablets in chronic kidney disease patients on haemodialysis

BACKGROUND Sevelamer carbonate is an improved, buffered form of sevelamer hydrochloride developed for the treatment of hyperphosphataemia in CKD patients. Sevelamer carbonate formulated as a powder for oral suspension presents a novel, patient-friendly alternative to tablet phosphate binders. This study compared the safety and efficacy of sevelamer carbonate powder with sevelamer hydrochloride ...

متن کامل

PA21, a novel phosphate binder, improves renal osteodystrophy in rats with chronic renal failure

The effects of PA21, a novel iron-based and non-calcium-based phosphate binder, on hyperphosphatemia and its accompanying bone abnormality in chronic kidney disease-mineral and bone disorder (CKD-MBD) were evaluated. Rats with adenine-induced chronic renal failure (CRF) were prepared by feeding them an adenine-containing diet for four weeks. They were also freely fed a diet that contained PA21 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2014