Determination of the density of human nuclear cataract lenses
نویسندگان
چکیده
The aim of the present study was to detect senile nuclear cataract lens density and provide a quantitative measurement of lens density for the long-term clinical observation of cataracts. An Anterior Segment Analysis System was used to detect the lens density of 422 simple senile cataract eyes and normal contralateral eyes. The density values were taken at the optical axis at various depths measured from the anterior capsule. The differences in lens density at various photographic orientations and in various nuclear grading groups were investigated. The density at 90˚ orientation was larger than that at 30 and 150˚ (P<0.05). The density was reduced beyond the 1.0-mm depth point in all the lenses. Prior to the 2.5-mm depth point, there were differences among the five grade groups (P<0.05). Beyond the 3.0-mm depth point, values in all the grade groups were low and not significantly different (P>0.05). In the grade 4 group, the decrease was more evident. The average density values at all the depth points showed a tendency to increase with increasing nuclear grade. Measuring the density of the anterior half of the lens at 90˚ orientation is therefore more reliable compared with that of the posterior half and at other orientations. Results of the present study have shown that the Anterior Segment Analysis System may be used to detect senile nuclear cataract lens density and provide a quantitative measurement of lens density for long-term clinical observation of cataracts.
منابع مشابه
Does Diarrhoea Causes Cataract? Can Cataract be Prevented by Aspirin?
Loss of transparency of the lens is termed cataract which is one of the commonest causes of blindness throughout the world. This major health problem appears to be much commoner in many developing countries such as India and Pakistan, where it causes visual disability at a substantially earlier age and several hypotheses have been put forward to explain this higher prevalence in these areas. Re...
متن کاملProtein-bound kynurenine decreases with the progression of age-related nuclear cataract.
PURPOSE Posttranslational modification by UV filters is a key event in human lenses that appears to be largely responsible for normal age-dependent yellowing. It has been proposed that subsequent reactions of these covalently bound UV filters may also be involved in the genesis of age-related nuclear cataract. To examine this hypothesis, the levels of kynurenine-lysine and kynurenine-histidine ...
متن کاملMelatonin Reduces Cataract Formation and Aldose Reductase Activity in Lenses of Streptozotocin-induced Diabetic Rat
Background: The relationship between the high activity of aldose reductase (AR) and diabetic cataract formation has been previously investigated. The purpose of the present study was to determine the preventing effect of melatonin on streptozotocin (STZ)-induced diabetic cataract in rats.Methods: 34 adult healthy male Sprague-Dawely rats were divided into four groups. Diabetic control and diabe...
متن کاملایجاد یک مدل تجربی آب مروارید در جنین جوجه
Background and Aim: Cataract is a major occular disease that causes blindness in many developing countries of the world. Experimental model of cataract is a first necessity to study the preventive factors of cataract progression. Several studies have shown that some glucocorticoides such as Dexamethasone (DEX) can induce cataract. The aim of this study was to form cataract in chick embryo. Mate...
متن کاملReproducibility of the NEI Scheimpflug Cataract Imaging System.
PURPOSE The NEI Scheimpflug Cataract Imaging System was developed to allow for easy, accurate and reproducible image analysis of nuclear cataracts. This study was undertaken to determine the reproducibility of densitometric measurements of the lens nucleus using this modified system. METHODS Replicate Zeiss Scheimpflug images of the lenses in 143 eyes were obtained by one photographer. Normal...
متن کامل