Pii: S0730-725x(01)00399-x

نویسندگان

  • Sharon Gustard
  • Jalal Fadili
  • Emma J. Williams
  • Laurance D. Hall
  • T. Adrian Carpenter
  • Matthew Brett
  • Edward T. Bullmore
چکیده

The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quantify variability in activation between orientations and between subjects. We also assessed signal detection accuracy in voxels across the whole brain by using a finite mixture model to fit receiver operating characteristic (ROC) curves to the data. Preliminary findings suggest that suprathreshold cluster characteristics demonstrate high motor reproducibility across subjects and orientations, although a significant difference between slice orientations in number of activated voxels was demonstrated in left motor cortex but not cerebellum. Subtle inter-orientation differences are highlighted in the ROC analyses, which are not obvious by ANOVA; the oblique axial slice orientation offers the highest signal detection accuracy, whereas coronal slices give the lowest. © 2001 Elsevier Science Inc. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0730-725x(01)00428-3

The subtle signal changes in functional magnetic resonance imaging (fMRI) can be easily overwhelmed by noise of various origins. Spikes in the collected fMRI raw data often arise from high-duty usage of the scanner hardware and can introduce significant noise in the image and thereby in the image time series. Consequently, the spikes will corrupt the functional data and degrade the result of fu...

متن کامل

Pii: S0730-725x(00)00154-5

We describe an MR-compatible ventilator that is computer controlled to generate a variety of breathing patterns, to minimize image degrading effects of breathing motion, and to support delivery of gas anesthesia and experimental inhalational gases. A key feature of this ventilator is the breathing valve that attaches directly to the endotracheal tube to reduce dead volume and allows independent...

متن کامل

Pii: S0730-725x(01)00436-2

Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNF...

متن کامل

Pii: S0730-725x(01)00393-9

Electric Current Density Imaging (CDI) is a new modality of magnetic resonance imaging that enables electric current distribution imaging in conductive samples containing water. So far, two CDI techniques have been in use: DC-CDI operating at zero frequency and RF-CDI operating at the RF Larmor frequency. In this paper we present a new CDI technique, which extends the CDI frequency range to alt...

متن کامل

Pii: S0730-725x(01)00419-2

With the increasing interest in phased arrays in magnetic resonance imaging, imaging system receivers capable of acquiring larger number of parallel signals are needed. Suggested techniques for rapid imaging propose the use of arrays with as many as 128 elements. While simply duplicating the number of receiver chains as needed is a viable technique, it quickly becomes both cumbersome and expens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000