Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences
نویسندگان
چکیده
Eighteen consecutive patients, treated with a Taylor Spatial Frame for complex tibia conditions, gave their informed consent to undergo Na(18)F(-) PET/CT bone scans. We present a Patlak-like analysis utilizing an approximated blood time-activity curve eliminating the need for blood aliquots. Additionally, standardized uptake values (SUV) derived from dynamic acquisitions were compared to this Patlak-like approach. Spherical volumes of interest (VOIs) were drawn to include broken bone, other (normal) bone, and muscle. The SUV m (t) (m = max, mean) and a series of slopes were computed as (SUV m (t i ) - SUV m (t j ))/(t i - t j ), for pairs of time values t i and t j . A Patlak-like analysis was performed for the same time values by computing ((VOI p (t i )/VOI e (t i ))-(VOI p (t j )/VOI e (t j )))/(t i - t j ), where p = broken bone, other bone, and muscle and e = expected activity in a VOI. Paired comparisons between Patlak-like and SUV m slopes showed good agreement by both linear regression and correlation coefficient analysis (r = 84%, r s = 78%-SUVmax, r = 92%, and r s = 91%-SUVmean), suggesting static scans could substitute for dynamic studies. Patlak-like slope differences of 0.1 min(-1) or greater between examinations and SUVmax differences of ~5 usually indicated good remodeling progress, while negative Patlak-like slope differences of -0.06 min(-1) usually indicated poor remodeling progress in this cohort.
منابع مشابه
Can Na18F PET/CT Be Used to Study Bone Remodeling in the Tibia When Patients Are Being Treated with a Taylor Spatial Frame?
Monitoring and quantifying bone remodeling are of interest, for example, in correction osteotomies, delayed fracture healing pseudarthrosis, bone lengthening, and other instances. Seven patients who had operations to attach an Ilizarov-derived Taylor Spatial Frame to the tibia gave informed consent. Each patient was examined by Na(18)F PET/CT twice, at approximately six weeks and three months a...
متن کاملFalse-positive FDG PET CT Scan in Vertebral Hemangioma
FDG PET CT scan is considered to be a sensitive tool to detect skeletal metastasis in known malignancies. However, it’s high sensitivity and low specificity may account for false positive diagnosis in cases of trauma, infection, inflammation and other benign conditions. Skeletal hemangioma is one of the common benign conditions which are typically ametabolic on FDG PET CT with no uptake on bone...
متن کاملAnalysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases
Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...
متن کاملA novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملCan Spatiotemporal Fluoride (18F−) Uptake be Used to Assess Bone Formation in the Tibia? A Longitudinal Study Using PET/CT
BACKGROUND When a bone is broken for any reason, it is important for the orthopaedic surgeon to know how bone healing is progressing. There has been resurgence in the use of the fluoride (18F-) ion to evaluate various bone conditions. This has been made possible by availability of positron emission tomography (PET)/CT hybrid scanners together with cyclotrons. Absorbed on the bone surface from b...