Hypersensitivity to Implant Debris
نویسنده
چکیده
Total Joint Replacements (TJR) have been extremely successful over the past 50 years, restoring mobility and function to millions of people each year. However, over time these implants need replacing for a number of reasons, such as infection or increasing immune reactivity to implant debris. All implant metals degrade in vivo, and the released products biologically interact locally and systemically. Local and/or systemic immune reactivity to implant debris may become excessive, specifically to one or more of the materials (metals) used in the implant alloys. When this excessive reactivity to implant debris involves the adaptive immune system where lymphocytes respond to specific stimuli it can be characterized as a sensitivity or hypersensitivity response. Dermal hypersensitivity reactions to metals (such as Nickel) are common and affect approximately 10–15% of the population in USA and Europe. In its extreme form, metal sensitivity exists as a relatively rare complication in only a few highly susceptible patients with joint replacements (i.e., less than 1% of joint replacement recipients). However, the role of implant-related metal sensitivity in implant performance is likely underreported due to the scarcity of diagnostic testing. The person-dependent mechanism(s) by which metal sensitivity occurs in some people and not others has not been completely explored with current hypersensitivity testing techniques. This issue is becoming increasing popular due to recent failures of metal-onmetal hips and increasing numbers of joint replacement procedures, worldwide. Better materials and availability of appropriate immunologic testing (e.g., LTT) will likely enhance future assessment of patients susceptible to hypersensitivity responses. N.J. Hallab (*) Department of Orthopedic Surgery, Rush Medical College, 1653 W. Congress Parkway, Chicago, IL 60612, USA e-mail: [email protected] N. Eliaz (ed.), Degradation of Implant Materials, DOI 10.1007/978-1-4614-3942-4_12, # Springer Science+Business Media New York 2012 329
منابع مشابه
A review of the biologic effects of spine implant debris: Fact from fiction
BACKGROUND Biologic-reactivity to implant-debris is the primary determinant of long-term clinical performance. The following reviews: 1) the physical aspects of spinal-implant debris and 2) the local and systemic biologic responses to implant debris. METHODS Methods included are: 1) gravimetric wear analysis; 2) SEM and LALLS; 3) metal-ion analysis; 4) ELISA, toxicity testing, patch testing; ...
متن کاملTitanium allergy: could it affect dental implant integration?
PURPOSE Degradation products of metallic biomaterials including titanium may result in metal hypersensitivity reaction. Hypersensitivity to biomaterials is often described in terms of vague pain, skin rashes, fatigue and malaise and in some cases implant loss. Recently, titanium hypersensitivity has been suggested as one of the factors responsible for implant failure. Although titanium hypersen...
متن کاملForeign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion
The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against...
متن کاملChemokines Associated with Pathologic Responses to Orthopedic Implant Debris
Despite the success in returning people to health saving mobility and high quality of life, the over 1 million total joint replacements implanted in the US each year are expected to eventually fail after approximately 15-25 years of use, due to slow progressive subtle inflammation to implant debris compromising the bone implant interface. This local inflammatory pseudo disease state is primaril...