An electro-physiological device to assess status of vitreous transparency.

نویسندگان

  • M Gupta
  • Y Gupta
  • P N Singh
چکیده

INTRODUCTION Evaluation of optical media is important in ophthalmic practice. OBJECTIVE to design and tryout an electro-physiological device in order to assess the transparency of the vitreous. MATERIALS AND METHODS A media-meter was designed where a light sensitive sensor was placed on the cornea and adjoining sclera during the process of trans-illumination. The trans-corneal (TC) and trans-scleral (TS) light transmittance were recorded objectively. By standardizing these readings on normal eyes, it was possible to suspect any cause of vitreous turbidity in eyes where the transmittance of light was observed to be less than the normal readings. STATISTICS Media-meter values were compared using Student's unpaired t- test for comparison between both the groups. Pearson or Spearman correlation coefficients were calculated for pooled media-meter values obtained from patients with endophthalmitis. RESULTS The readings were obtained by TC and TS media-metry with white light in 20 eyes that served to standardize the device. The mean values for the intensity recorded on the media-meter were 206 to 74 Lux and after log-values conversion were 2.14 (range 2.36 to 1.87) and 45 to 31 Lux and after log conversion 1.60 (range 1.66 to 1.49) for TC and TS media-meter respectively. There was a highly significant difference between normal eye readings and the corresponding values obtained for TC and TS media-meter values in eyes with endophthalmitis. CONCLUSION The media-meter can be used to evaluate vitreous transparency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Conveyable Device for Electro-drainage of Thorax

Chest tube is a flexible plastic tube used to discharge secretion in the cavity between the lungs and chest named pleural cavity. Normally, there is a small amount of fluid in the cavity between the lungs and chest; This fluid helps the movement of lungs during breathing without abrasion. Entrance of bit of air, blood or pus because injury in the pleural cavity can prevent the lungs from fully ...

متن کامل

Simulation and Design of an Organic Quantum Film Electrooptic Switch

In this paper the simulation and design of a quantum-film electro-optic switch is considered. This photonic device, is made from a new organic dipolar material called MNA or 2-methyl-4 nitroaniline, which possesses a high merit in comparison with it's inorganic counterparts (e.g. LiNbO3, GaAs, InSb, Quartz, etc). Montecarlo method is used to simulate the photon-it-electron interaction in this m...

متن کامل

Evaluation of the Academic Preparedness and Final Performance of Students of Electro-Techniques Field in Technical and Vocational Schools

Evaluation of the Academic Preparedness and Final Performance of Students of Electro-Techniques Field in Technical and Vocational Schools A.A. Khallaaghi, Ph.D. E. Ghaasemi Pooyaa, Ph.D. To determine the extent of the electro-techniques students' preparedness in order to assess their success in learning the practical skills and attitudes prescribed by the curriculum, a cluster sam...

متن کامل

Influences of Device Architectures on Characteristics of Organic Light-Emitting Devices Incorporating Ambipolar Blue-Emitting Ter(9,9-diarylfluorenes)

In this article, we report the studies of various device architectures of organic lightemitting devices (OLEDs) incorporating highly efficient blue-emitting and ambipolar carriertransport ter(9,9-diarylfluorene)s, and their influences on device characteristics. The device structures investigated include single-layer devices and multilayer heterostructure devices employing the terfluorene as one...

متن کامل

Is Optical Coherence Tomography a Useful Tool to Objectively Detect Actual Posterior Vitreous Adhesion Status?

Purpose. To objectively detect true posterior vitreous cortex (PVC) adhesion status using a commercially available swept-source OCT device (DRI OCT-1, Atlantis(©)). Material and Methods. Case report, review of the literature, and methodical discussion of concepts to improve OCT-guided PVC imaging. Results. Standard OCT imaging misdiagnosed PVC adhesion status as totally detached in this case re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nepalese journal of ophthalmology : a biannual peer-reviewed academic journal of the Nepal Ophthalmic Society : NEPJOPH

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2011