Multicenter evaluation of methods to quantitate human immunodeficiency virus type 1 RNA in seminal plasma.

نویسندگان

  • S A Fiscus
  • D Brambilla
  • R W Coombs
  • B Yen-Lieberman
  • J Bremer
  • A Kovacs
  • S Rasheed
  • M Vahey
  • T Schutzbank
  • P S Reichelderfer
چکیده

We have evaluated two commercially available kits (AMPLICOR MONITOR [Roche] and NASBA HIV-1 QT or NucliSens HIV-1 QT [Organon Teknika]) and two noncommercial methods for the accurate quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in seminal plasma. The same panels of coded specimens were tested on four separate occasions. Laboratories using the commercial assays employed silica beads to isolate HIV-1 RNA, which removed inhibitory factors sometimes found in seminal plasma. Sensitivities and specificities, respectively, for each assay were as follows: AMPLICOR MONITOR, 100 and 73%; NASBA HIV-1 QT, 84 and 100%; NucliSens HIV-1 QT, 99 and 98%; and noncommercial assays, 91 and 73%. When results from the laboratory that was inexperienced with the silica bead extraction method were excluded from the analysis, specificity for the Roche assay increased to 100%. The commercial assays demonstrated highly reproducible results, with intra-assay standard deviations (measured in log(10) RNA copies/milliliter of seminal plasma) ranging from 0.11 to 0.32; those of the noncommercial assays ranged from 0.12 to 0.75. Differences in mean estimated HIV-1 RNA concentrations were </=0.67 log(10) and were greater at low viral loads. Suspension matrices that used blood plasma or seminal plasma did not make a difference in recovery of HIV-1 RNA, which suggested that blood plasma specimens can be used as external controls for seminal plasma assays. More variation in the HIV-1 RNA viral loads was observed in the seminal plasma values than in the blood plasma values when paired specimens from HIV-1-infected men were tested. Quantitation of HIV-1 RNA in seminal plasma can be reliably accomplished using two commercially available assays, and may be incorporated into the evaluations of HIV-1 seropositive men enrolled in clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O-2: Prospective Evaluation of the ThreatRelated to the Use of Seminal Fractions fromHepatitis C Virus-Infected Men in Assisted ReproductiveTechniques

Background: The risk of hepatitis C virus (HCV) transmission during assisted reproductive techniques (ARTs) is still disputed and no report concerning its prospective evaluation is available. The aim of this 4-year follow-up multicentre study that enrolled 86 HCV-serodiscordant couples was to determine whether a sperm-processing method was able to reduce levels of HCV in semen and the risk of H...

متن کامل

Quantitation of human immunodeficiency virus type 1 RNA in different biological compartments.

Little information is available describing viral loads in body fluids other than blood. In addition, the suitability of commercially available assays for human immunodeficiency virus type 1 (HIV-1) RNA quantitation has not been evaluated in most nonblood fluids. We compared Organon Teknika's nucleic acid sequence-based amplification method (NASBA) and Roche's Amplicor HIV-1 Monitor (reverse tra...

متن کامل

The Prevalence of Hepatitis B, Hepatitis C, and Human Immunodeficiency Virus Infections among β-thalassemia Major: A Multicenter Survey in Lorestan, West of Iran

Background: Although regular frequent blood transfusion improves overall survival of multi-transfused patients like &beta;-thalassemic ones, it carries a definite risk of infection with blood-borne viruses such as viral hepatitis. This study was done to determine seropositivity of hepatitis B virus (HBV), hepatitis C virus (HCV), and Human Immunedeficiency Virus (HIV) infections among &beta;-th...

متن کامل

Cytomegalovirus Active Infection in Persons Infected with Human Immunodeficiency Virus

Background and Objective: Cytomegalovirus (CMV), one of the most common opportunistic pathogens in patients infected with human immunodeficiency virus (HIV), can cause the diseases such as encephalitis, pneumonia, and chorioretinitis. This study aimed at molecular studying of CMV infection in individuals infected with the human immunodeficiency virus. Material and Methods: In this study, 50 ven...

متن کامل

In vitro Assessment of Antiviral Activity of Cold Atmospheric Pressure Plasma Jet against the Human Immunodeficiency Virus (HIV)

Introduction: The human immunodeficiency virus (HIV) is a threat to global health and the need for finding new methods of antivirus research, in particular against HIV has increased in recent years. In this study, we investigated the ability of the cold atmospheric pressure plasma jet (CAPPJ) using helium to inhibit the replication of HIV virions. Methods: Single cycle replicable HIV (SCR-HIV) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2000