Analytical Solution to 3D SPECT Reconstruction with Non-uniform Attenuation, Scatter, and Spatially-variant Resolution Variation for Variable Focal-length Fan-beam Collimators

نویسندگان

  • Junhai Wen
  • Hongbing Lu
  • Tianfang Li
  • Zhengrong Liang
چکیده

In the past decades, analytical (non-iterative) methods have been extensively investigated and developed for the reconstruction of three-dimensional (3D) single-photon emission computed tomography (SPECT). However, it becomes possible only recently when the exact analytic non-uniform attenuation reconstruction algorithm was derived. Based on the explicit inversion formula for the attenuated Radon transform discovered by Novikov (2000), we extended the previous researches of inverting the attenuated Radon transform of parallel-beam collimation geometry to fan-beam and variable focal-length fan-beam (VFF) collimators and proposed an efficient, analytical solution to 3D SPECT reconstruction with VFF collimators, which compensates simultaneously for non-uniform attenuation, scatter, and spatially-variant or distance-dependent resolution variation (DDRV), as well as suppression of signal-dependent non-stationary Poisson noise. In this procedure, to avoid the reconstructed images being corrupted by the presence of severe noise, we apply a Karhune-Loève (K-L) domain adaptive Wiener filter, which accurately treats the nonstationary Poisson noise. The scatter is then removed by our scatter estimation method, which is based on the energy spectrum and modified from the triple-energy-window acquisition protocol. For the correction of DDRV, a distancedependent deconvolution is adapted to provide a solution that realistically characterizes the resolution kernel in a real SPECT system. Finally image is reconstructed using our VFF non-uniform attenuation inversion formula.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Ray-driven analytical fan-beam SPECT reconstruction with nonuniform attenuation

Single-photon emission computed tomography (SPECT) is based on the measurement of radiation emitted by a radiotracer injected into the patient. Because of photoelectric absorption and Compton scatter, the γ photons are attenuated inside the body before arriving at the detector. A quantitative reconstruction must consider the attenuation, which is usually non-uniform. Novikov and Natterer had de...

متن کامل

An Analytical Inversion of the Nonuniformly Attenuated Radon Transform With Variable Focal-Length Fan-Beam Collimators

Single photon emission computed tomography (SPECT) is based on the measurement of radiation emitted by a radiotracer injected into the patient. Because of photoelectric absorption and Compton scatter, the gamma photons are attenuated inside the body before arriving at the detector. A quantitative reconstruction must consider the attenuation, which is usually nonuniform. Novikov has derived an e...

متن کامل

Analytical Compensation for Spatially Variant Detector Response in SPECT With Varying Focal-Length Fan-Beam Collimators

The authors present a new method to compensate for the spatially variant detector response in single photon emission computed tomography (SPECT) with varying focal-length fan-beam (VFF) geometry. In this method, the deblurred projection is explicitly expressed as an integral of the collimator blurred data and the fully calibrated system kernel matrix with certain transforms. It needs a little m...

متن کامل

Towards Analytical Solution for 3D SPECT Reconstruction with Non- Uniform Attenuation and Distance-Dependent Resolution Variation: A Monte Carlo Simulation Study

Based on Kunyansky’s and our previous work, an efficient, analytical solution to the reconstruction problem of myocardial perfusion SPECT has been developed that allows simultaneous compensation for non-uniform attenuation, scatter, and system-dependent resolution variation, as well as suppression of signal-dependent Poisson noise. To avoid reconstructed images being corrupted by the presence o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003