Do media players cause interference with pacemakers?

نویسندگان

  • Jay P Thaker
  • Mehul B Patel
  • Ashok J Shah
  • Valdis V Liepa
  • Joseph D Brunett
  • Krit Jongnarangsin
  • Joseph C Gardiner
  • Ranjan Thakur
چکیده

BACKGROUND Electrical devices generate electromagnetic fields that may interfere with pacemakers. Media players cause telemetry interference with pacemakers, but it is not known whether they cause direct interference with pacemakers. The purpose of this study was to examine the interaction between pacemakers and 3 different media players. METHODS In this prospective, randomized study, 54 patients with dual chamber pacemakers who were in sinus rhythm underwent baseline observation, followed by observation under telemetry communication. These patients were then randomly evaluated with 3 media players (iPod 3G, iPod Photo, and iPod Touch Apple, Cupertino, CA) with and without telemetry communication for 1 minute each. Patients were monitored for pacemaker malfunction using a single-channel ECG during exposure to media players. The pacemaker was interrogated after each exposure and an interrogation report was printed for evaluation. Pacemaker interference was categorized as type I, II, or III. Types I and II interference described telemetry interference and type III interference was defined as any direct interference with pacemaker function or programmed parameters. RESULTS A total of 54 patients (29 men and 25 women; mean age 77.2 +/- 9.3 y) were evaluated. In total, of the 162 tests (for telemetry interference) 36.4% were positive (Type I and II). Type III interference was also evaluated in 162 tests and none showed any evidence of direct interference. CONCLUSION Media players cause telemetry interference with pacemakers, but they do not directly interfere with pacemaker function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of telemetry interference with pacemakers caused by digital media players.

BACKGROUND Contemporary implantable heart rhythm devices communicate multiple complex data simultaneously using radiofrequency telemetry. Interference in communication can expose them to the risk of potential corruption, leading to adverse clinical consequences. METHODS & RESULTS We studied the characteristics of interference with uplink (real time intracardiac electrograms, marker channel, a...

متن کامل

Pacemakers: some of the risks and complications you are not warned about.

Pacemaker technology has advanced rapidly over the last decade. A lot of everyday interference can be regarded as transient. The media tend to cover stories of relatively insignificant transient interference incurred by pacemaker wearers while many manuals gloss over the high risks, some potentially life-threatening. These include the reliability of pacemakers and the use of monopolar diathermy...

متن کامل

Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators.

BACKGROUND Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets, which are small in size but produce strong magnetic fields, have become widely available in recent years. Therefore, NdFeB magnets may be associated with an emerging risk of device interference. OBJECTIVE We conducted a clin...

متن کامل

Interference between dental electrical devices and pacemakers or defibrillators: results from a prospective clinical study.

BACKGROUND The authors aimed to determine whether electrical dental devices would interfere with the function of cardiac pacemakers or implantable cardioverter defibrillators (ICDs) in humans. METHODS The authors exposed asymptomatic nonpacemaker-dependent patients to commonly used electrical dental equipment (for example, battery-operated curing lights, ultrasonic baths, ultrasonic scalers, ...

متن کامل

An Analysis of A Fishing Model with Nonlinear Harvesting Function

In this study, considering the importance of how to exploit renewable natural resources, we analyzea shing model with nonlinear harvesting function in which the players at the equilibrium pointdo a static game with complete information that, according to the calculations, will cause a wasteof energy for both players and so the selection of cooperative strategies along with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical cardiology

دوره 32 11  شماره 

صفحات  -

تاریخ انتشار 2009