Measurement of neutron detection efficiencies in NaI using the Crystal Ball detector

نویسندگان

  • T.D.S. Stanislaus
  • D. D. Koetke
  • C. Allgower
  • V. Bekrenev
  • K. Benslama
  • E. Berger
  • W. J. Briscoe
  • M. Clajus
  • J. R. Comfort
  • K. Craig
  • A. Gibson
  • D. Isenhower
  • T. Kasprzyk
  • N. Knecht
  • A. Koulbardis
  • N. Kozlenko
  • S. Kruglov
  • T. Kycia
  • G. J. Lolos
  • I. Lopatin
  • R. Manweiler
  • A. Marusic
  • S. McDonald
  • Z. Papandreou
  • D. Peaslee
  • R. J. Peterson
  • N. Phaisangittisakul
  • M. Pulver
  • A. F. Ramirez
  • M. Sadler
  • A. Shafi
  • I. Slaus
  • H. Spinka
  • A. Starostin
  • H. M. Staudenmaier
  • I. Supek
  • J. Thoms
  • W. B. Tippens
چکیده

We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball (CB) detector obtained from a study of p p !p8n reactions at the Brookhaven National Laboratory AGS. A companion *Corresponding author. Tel.: +1-219-464-5377; fax: +1-219-464-5489. E-mail address: [email protected] (D.D. Koetke). Present Address: Indiana University Cyclotron Facility, Bloomington, IN 47408, USA. Present Address: NOVA R&D, Inc., Riverside, CA 92507, USA. Present Address: Ball State University, Muncie, IN 47306, USA. Deceased. Present Address: Brookhaven National Laboratory, Upton, NY 11973, USA. Present Address: TRIUMF, Vancouver, BC, Canada V6T 2A3. Present Address: Nuclear Physics Division, U.S. Department of Energy, Germantown, MD 20874, USA. 0168-9002/01/$ see front matter # 2001 Elsevier Science B.V. All rights reserved. PII: S 0 1 6 8 9 0 0 2 ( 0 1 ) 0 0 1 8 0 2 GEANT-based Monte Carlo study has been done to simulate these reactions in the CB, and a comparison with the data is provided. # 2001 Elsevier Science B.V. All rights reserved. PACS: 29.40.Vj; 29.85.+c; 28.20. v

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

Passive neutron area monitor with CR39

Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

The safety of a landmine detection system using graphite and polyethylene moderator

Background: Several landmine detection methods, based on nuclear techniques, have been suggested up to now. Neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. In this paper an optimized (safe and effective) moderating structure using an 241Am-Be neutron source for detecting landmines has been invest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001