Integration of a high-NA light microscope in a scanning electron microscope.

نویسندگان

  • A C Zonnevylle
  • R F C Van Tol
  • N Liv
  • A C Narvaez
  • A P J Effting
  • P Kruit
  • J P Hoogenboom
چکیده

We present an integrated light-electron microscope in which an inverted high-NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high-resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub-10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum-compatible immersion oil. For a 40-nm-diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Light and electron microscope of grass carp (Ctenopharyngodon idella) organs following exposure to various sublethal concentrations of diazinon

Histopathological effects of different sublethal concentrations (1, 2 and 4 mg/l) of diazinon, an organophosphorus pesticide, on gill, liver, spleen and kidney of grass carp (Ctenopharyngodon idella) were studied after 1, 7, 15, 30 and 45 days post-exposing fishes weighting 850 ± 155 g to the toxicant for 12 hours at 18-22ºC. In addition, tissues of nostril were examined for transmission electr...

متن کامل

Light and electron microscope of grass carp (Ctenopharyngodon idella) organs following exposure to various sublethal concentrations of diazinon

Histopathological effects of different sublethal concentrations (1, 2 and 4 mg/l) of diazinon, an organophosphorus pesticide, on gill, liver, spleen and kidney of grass carp (Ctenopharyngodon idella) were studied after 1, 7, 15, 30 and 45 days post-exposing fishes weighting 850 ± 155 g to the toxicant for 12 hours at 18-22ºC. In addition, tissues of nostril were examined for transmi...

متن کامل

Simultaneous Correlative Scanning Electron and High-NA Fluorescence Microscopy

Correlative light and electron microscopy (CLEM) is a unique method for investigating biological structure-function relations. With CLEM protein distributions visualized in fluorescence can be mapped onto the cellular ultrastructure measured with electron microscopy. Widespread application of correlative microscopy is hampered by elaborate experimental procedures related foremost to retrieving ...

متن کامل

Considerations on a laser-scanning-microscope with high resolution and depth of field.

In conventional light microscopy, the depth of focus is severely limited. This limitation might be overcome by a light optical scanning procedure. In this procedure, the specimen surface is scanned point for point by a focused laser beam. The image of the specimen surface is generated by an electronic system, similar to the procedure used in the scanning electron microscope. Possibilities to de...

متن کامل

Branchial chamber structure and osmoregulatory function in the prawn, Palaemon elegans (Crustacea: Decapoda) from the Caspian Sea

The structure, ultrastructure and osmoregulatory function of the branchial chamber were investigated in Palaemon elegans (Rathke, 1837) by light microscope, electron microscope and immunohistochemistry methods, respectively. Each chamber possesses a branchiostegite, 3 epipodites and 8 phyllobranchiate gills. The lamellae are attached along the two outer surfaces of the triangular gill axis. Ult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of microscopy

دوره 252 1  شماره 

صفحات  -

تاریخ انتشار 2013