Effect of icodextrin dialysis solution on body weight and fat accumulation over time in CAPD patients.

نویسندگان

  • Kyu-Hyang Cho
  • Jun-Young Do
  • Jong-Won Park
  • Kyung-Woo Yoon
چکیده

BACKGROUND The purpose of this study was to analyse the changes of body composition and the effects of icodextrin dialysis solution over time on peritoneal dialysis (PD) in continuous ambulatory peritoneal dialysis (CAPD) patients. METHODS Among 183 incident patients, 75 patients finished a complete 36-month protocol. Clinical indices including daily glucose absorption and body composition, by bioelectrical impedance analysis (BIA), were measured in both groups (icodextrin group: 36 patients, non-icodextrin group: 39 patients) at the 1st (baseline), 12th, 24th and 36th months. RESULTS There were significant increases in body weight and fat mass during the 36 months after initiation of CAPD. It was found that 78% of 3 years of weight gain occurred during the first year and 88% of weight gain at the end of the first year was fat mass gain. The icodextrin group showed a significantly lower percent of fat mass during the first 36 months (P < 0.05) and also less changes in body weight, fat mass, percent (%) fat mass, visceral fat area and waist/hip ratio at 1, 2 and 3 years than the non-icodextrin group. There were no significant changes in total body water (TBW), extra cellular fluid (ECF), oedema index and lean body mass (LBM) through comparable daily and ultrafiltration volume (UFV) between the two groups during the initial 3 years. Factors associated with the higher percent of fat mass gain over time on peritoneal dialysis were age, diabetes, gender (female) and non-icodextrin group (all, P < 0.01, generalized estimating equation). CONCLUSION The application of icodextrin solution may be a better option to alleviate excessive fat gain over time for patients on PD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of volume overload with cycler-assisted versus continuous ambulatory peritoneal dialysis.

BACKGROUND AND OBJECTIVES Cycler-assisted peritoneal dialysis (CCPD) has been associated with decreased sodium removal compared with continuous ambulatory peritoneal dialysis (CAPD) as a result of peritoneal sodium sieving during the short dwells that are associated with CCPD. This may have adverse consequences for management of extracellular fluid volume (ECFV). This study compared ECFV in pat...

متن کامل

Sodium removal in peritoneal dialysis: the role of icodextrin and peritoneal dialysis modalities.

One of the main goals of dialysis is the control of extracellular volume, because inadequate sodium and fluid removal result in fluid overload and increased mortality. In the present study, we evaluated the roles of continuous ambulatory peritoneal dialysis (CAPD), continuous cycling peritoneal dialysis (CCPD), and the use of icodextrin on sodium removal in 29 patients (n = 18 on CAPD, n = 11 o...

متن کامل

Effects of icodextrin peritoneal dialysis solution on the peritoneal membrane in the STZ-induced diabetic rat model with partial nephrectomy.

BACKGROUND Application of icodextrin-based peritoneal dialysis fluid (PDF) provides a potential benefit in patients with diabetes and end-stage renal failure treated with continuous ambulatory peritoneal dialysis (CAPD) because of better ultrafiltration capacity and avoidance of direct glucose exposure. We examined the effect of glucose and icodextrin-based PDF on histological alterations of pe...

متن کامل

Effects of different peritoneal dialysis fluids on the TH1/TH2 balance.

BACKGROUND Peritoneal dialysis (PD) is associated with a depression of T cell function, as suggested by the impaired production of cytokines by Th cells collected from PD patients. Although treatment biocompatibility could be implicated in this immune dysfunction, it has been poorly investigated, thus far. Therefore, we undertook a study aiming to analyze the effects of different peritoneal dia...

متن کامل

Comparison of Peritoneal Low-Molecular-Weight-Protein-Removal in CCPD and CAPD Patients Based on C-Terminal Agrin Fragment Clearance.

BACKGROUND/AIMS This study compares the peritoneal elimination of the low-molecular-weight-protein (LMWP) C-terminal agrin fragment (tCAF, size 22 kDa), a promising biomarker for kidney function, in continuous cycling peritoneal dialysis (CCPD) and continuous ambulatory peritoneal dialysis (CAPD). METHODS 103 sets of serum, 24h-urine and dialysate samples were obtained in 15 CCPD (63 sets) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2010