Detection of coronary artery stenosis in children with Kawasaki disease. Usefulness of pharmacologic stress 201Tl myocardial tomography.

نویسندگان

  • C Kondo
  • M Hiroe
  • T Nakanishi
  • A Takao
چکیده

This study determined the feasibility and accuracy of quantitative 201Tl myocardial single-photon emission computed tomography (SPECT) after dipyridamole infusion to detect coronary obstructive lesions in children with Kawasaki disease. 201Tl distribution after dipyridamole infusion was measured in 23 normal children, and with these normal values, quantitative analysis of SPECT was performed in 49 patients. Thirty-four patients had coronary stenosis 90% or greater on angiograms. Side effects resulting from systemic vasodilation were observed in about 70%. Angina pectoris and ischemic ST changes were observed only in patients with coronary stenosis. These symptoms disappeared after aminophylline infusion. Results of visual and quantitative analysis of SPECT were compared. SPECT data were shown on two-dimensional polar maps, and the extent and severity scores were calculated. The sensitivity of SPECT for detection of overall coronary stenosis was 91% (visual analysis) and 88% (quantitative analysis). The specificity of SPECT was 60% visually and 93% quantitatively. The sensitivity of quantitative analysis to detect individual coronary stenosis was similar to that of visual analysis. However, the specificity of visual analysis to detect individual coronary artery stenosis was significantly less than that of quantitative analysis. From these data, we conclude that quantitative analysis of myocardial SPECT after dipyridamole infusion is a safe and accurate diagnostic method for identifying coronary stenosis in children with Kawasaki disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Coronary Artery Stenosis in Children With Kawasaki Disease Usefulness of Pharmacologic Stress 201 TI Myocardial Tomography

This study determined the feasibility and accuracy of quantitative 2`T1 myocardial singlephoton emission computed tomography (SPECT) after dipyridamole infusion to detect coronary obstructive lesions in children with Kawasaki disease. 20`TI distribution after dipyridamole infusion was measured in 23 normal children, and with these normal values, quantitative analysis of SPECT was performed in 4...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

THALLIUM-201 STRESS TEST IN 156 PATIENTS WITH SUSPECTED CORONARY ARTERY DISEASE

Currently, myocardial TI-201 scintigraphy is most often performed in conjunction with exercise stress testing in patients with suspected or known CAD. Stress thallium tests were performed for 156 patients with and without old myocardial infarctions complaining of chest pain. All of them underwent contrast coronary angiography. Perfusion defects were mostly manifested as reversible defects ...

متن کامل

Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.

We tested the hypothesis that 99mTc 2-methoxy-isobutyl-isonitrile (99mTc MIBI), a new radiopharmaceutical for myocardial perfusion imaging, provides accurate noninvasive detection of coronary artery disease (CAD). Imaging in patients after exercise and at rest with 99mTc MIBI was compared with imaging after exercise and redistribution with 201Tl in 12 normal subjects and 38 patients with angiog...

متن کامل

Myocardial perfusion imaging with technetium-99m-Tc NOET: comparison with thallium-201 and coronary angiography.

UNLABELLED We compared TcN-NOET [bis(N-ethoxy, N-ethyl dithiocarbamato)nitrido 99mTc] and 201Tl images to estimate the utility of this compound in the detection of coronary artery disease (CAD). METHODS Twenty-five patients undergoing cardiac catheterization had stress-redistribution-reinjection 201Tl SPECT imaging, stress-delayed (2, 4 and 6 hr postinjection) and rest-delayed (4 hr postinjec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 1989