Validation of the automated reading and incubation system with Sensititre plates for antimicrobial susceptibility testing.
نویسندگان
چکیده
The present study compared the antimicrobial susceptibility testing (AST) results generated by the Automated Incubation and Reading System (ARIS) with custom Sensititre plates (TREK Diagnostic Systems, Cleveland, Ohio) and MicroScan PC10 GP and NUMIC10 GN plates interpreted with the WalkAway-96 system (Dade Behring, West Sacramento, Calif.) for gram-positive (GP) and gram-negative (GN) organisms as part of an in-house validation. A total of 326 isolates (3,689 antimicrobial agent-organism combinations) were evaluated. Sensititre plates were inoculated according to the instructions of the manufacturer with a suspension adjusted to a 0.5 McFarland standard, while the Prompt Inoculation System was used for the MicroScan plates. ARIS and the WalkAway system were used for automated reading of the Sensititre and MicroScan plates, respectively, at 18 to 24 h. The results were analyzed for essential (+/-1 twofold dilution) and categorical (sensitive, intermediate, or resistant) agreements. Plates that resulted in ARIS interpretations with major (falsely resistant) or very major (falsely susceptible) errors compared to the results obtained with the WalkAway system were read manually to corroborate instrument readings. Isolates for which very major or major errors were obtained and for which the results were not resolved by manual reading were retested in parallel. Isolates for which very major or major errors were obtained and for which the results were not resolved upon repeat testing were tested by the National Committee for Clinical Laboratory Standards M7-A5 frozen reference microdilution method. Essential agreement was 95.8% for 246 GN isolates. The following categorical error rates were obtained for the GN isolates: 1.3% minor errors, 0% major errors, and 0.4% very major errors. For 95 GP isolates, there was 93.5% essential agreement. Categorical error rates for GP isolates were 0.9% minor errors, 0.6% major errors, and 0.4% very major errors. ARIS-Sensititre is a diagnostic system feasible for use for automated AST in a clinical laboratory.
منابع مشابه
Evaluation of Sensititre automated reading and incubation system for automated reading of Sensititre broth microdilution susceptibility plates.
The Sensititre Automated Reading and Incubation System (ARIS) performs automated reading of Sensititre identification and susceptibility plates. ARIS susceptibility results were compared to manually read results. A total of 212 isolates (3352 organism-antimicrobial agent combinations) yielded 99.4% essential agreement and categorical error rates of 0.2% minor, 0% major, and 1.0% very major. ARI...
متن کاملDirect susceptibility testing of positive blood cultures by using Sensititre broth microdilution plates.
Traditional susceptibility testing of blood cultures requires overnight incubation in order to obtain isolated colonies. Susceptibility results can be reported up to 24 h sooner by using a bacterial pellet from the blood culture broth. This study evaluated the accuracy of direct susceptibility testing from positive ESP blood culture broths by using Sensititre broth microdilution plates compared...
متن کاملValidation of Sensititre Dry-Form Broth Microdilution Panels for Susceptibility Testing of Ceftazidime-Avibactam, a Broad-Spectrum-β-Lactamase Inhibitor Combination.
Ceftazidime-avibactam is a broad-spectrum-β-lactamase inhibitor combination in late-stage clinical development for the treatment of serious infections. In preparation for clinical microbiology laboratory use, a validation experiment was initiated to evaluate a commercial broth microdilution product (Sensititre dried MIC susceptibility system) compared to reference panels using 525 recent clinic...
متن کاملEvaluation of an Automated System for Reading and Interpreting Disk Diffusion Antimicrobial Susceptibility Testing of Fastidious Bacteria
Results of disk diffusion antimicrobial susceptibility testing depend on individual visual reading of inhibition zone diameters. Therefore, automated reading using camera systems might represent a useful tool for standardization. In this study, the ADAGIO automated system (Bio-Rad) was evaluated for reading disk diffusion tests of fastidious bacteria. 144 clinical isolates (68 β-haemolytic stre...
متن کاملComparison of the Vitek 2 antifungal susceptibility system with the clinical and laboratory standards institute (CLSI) and European Committee on Antimicrobial Susceptibility Testing (EUCAST) Broth Microdilution Reference Methods and with the Sensititre YeastOne and Etest techniques for in vitro detection of antifungal resistance in yeast isolates.
The commercial technique Vitek 2 system for antifungal susceptibility testing of yeast species was evaluated. A collection of 154 clinical yeast isolates, including amphotericin B- and azole-resistant organisms, was tested. Results were compared with those obtained by the reference procedures of both the CLSI and the European Committee on Antimicrobial Susceptibility Testing (EUCAST). Two other...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 41 5 شماره
صفحات -
تاریخ انتشار 2003