Simulation of partially coherent image formation in a compact soft X-ray microscope.

نویسندگان

  • Olov von Hofsten
  • Per A C Takman
  • Ulrich Vogt
چکیده

In this paper, we describe a numerical method of simulating two-dimensional images in a compact soft X-ray microscope using partially coherent illumination considerations. The work was motivated by recent test object images obtained by the latest generation in-house compact soft X-ray microscope, which showed diffraction-like artifacts not observed previously. The numerical model approximates the condenser zone plate as a secondary incoherent source represented by individually coherent but mutually incoherent source points, each giving rise to a separate image. A final image is obtained by adding up all the individual source point contributions. The results are compared with the microscope images and show qualitative agreement, indicating that the observed effects are caused by partially coherent illumination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D simulation of the image formation in soft x-ray microscopes.

In water-window soft x-ray microscopy the studied object is typically larger than the depth of focus and the sample illumination is often partially coherent. This blurs out-of-focus features and may introduce considerable fringing. Understanding the influence of these phenomena on the image formation is therefore important when interpreting experimental data. Here we present a wave-propagation ...

متن کامل

Partially Coherent Image Formation Theory for X-ray Microscopy

Partially coherent image formation theory for a full-field imaging microscope is introduced. Propagation of mutual coherence is presented following Huygens-Fresnel principle. The concept of mutual intensity, together with the quasimonochromatic condition under which it is valid, is also introduced. Detailed analysis of a microscope illuminated by a partially coherent source is presented. Mutual...

متن کامل

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

Acquiring molecular interference functions of X-ray coherent scattering for breast tissues by combination of simulation and experimental methods

Background: Recently, it has been indicated that X-ray coherent scatter from biological tissues can be used to access signature of tissue. Some scientists are interested in studying this effect to get early detection of breast cancer. Since experimental methods for optimization are time consuming and expensive, some scientists suggest using simulation. Monte Carlo (MC) codes are the best...

متن کامل

Partially coherent image formation with x-ray microscopes.

Image formation with partially coherent radiation is evaluated with the Hopkins formula and then applied to x-ray microscopy. Image characteristics expected from instruments with circular and annular pupils in partially coherent conditions are considered for two-point objects and a knife-edge object. The theoretically expected values for image characteristics that are easy accessible by an expe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 107 8  شماره 

صفحات  -

تاریخ انتشار 2007