Angular distributions of g rays from the Li„p,g... reaction at low energies

نویسندگان

  • K. I. Hahn
  • C. R. Brune
  • R. W. Kavanagh
  • W. K. Kellogg
چکیده

Angular distributions of the 14–17 MeV g rays from the Li~p ,g) reaction at Ep5450, 402, and 80 keV were measured at 0°<u lab<135°, using a BGO detector and a 28-mg/cm 2 LiF target. The angular distributions at Ep5450 and 402 keV agree with the previous results by Mainsbridge; at Ep580 keV the ground-state transition is anisotropic on the order of 20%, confirming recent results by Chasteler et al.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed.Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor.Method...

متن کامل

ar X iv : n uc l - th / 0 01 10 66 v 1 1 7 N ov 2 00 0 7 Li ( p , n ) NUCLEAR DATA LIBRARY FOR INCIDENT PROTON ENERGIES TO 150 MEV

Researchers at Los Alamos National Laboratory are considering the possibility of using the Low Energy Demonstration Accelerator, constructed at Los Alamos Neutron Science Center for the Accelerator Production of Tritium Project, as a neutron source. Evaluated nuclear data are needed for the p+ 7 Li reaction, to predict neutron production from thin and thick lithium targets. In this paper we des...

متن کامل

An in-vivo study on the energy dependence of X-ray biological effectiveness

Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...

متن کامل

Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study

Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The lina...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996