Development of radioimmunoassay for measurement of serum digoxin in digitalized patients using novel anti-digoxin antiserum.
نویسندگان
چکیده
There is an antiserum elicited by digoxin 3'-hemisuccinate-bovine serum albumin (BSA) conjugate possessing high specificity for digoxin. Our study focused on development of RIA using this novel antiserum for measurement of digoxin in serum from digitalized patients. The property of the new antiserum was investigated by RIA with digoxin 3'-hemisuccinyl-[3H]leucine. The separation of bound and free fractions was performed using a dextran-coated charcoal suspension. The new antiserum bound approximately 50% of digoxin 3'-hemisuccinyl-[3H]leucine with a final dilution of 1:30000. The intra- and inter-assay coefficients of variation were <9% in the range of 0.52-4.17 ng/ml. The mean digoxin concentration in serum samples (n=35) from digitalized patients was estimated to be 0.68 ng/ml, which was lower than its measurement of digoxin with the commercial antidigoxin BSA serum and monoclonal anti-digoxin. It is apparent that the RIA described here has sufficient precision. The RIA system was available for the measurement of digoxin in serum from digitalized patients.
منابع مشابه
Biol. Pharm. Bull. 28(2) 340—343 (2005)
the treatment of congestive heart failure and atrial fibrillation. It is important to measure digoxin in serum from digitalized patients because the therapeutic range of serum digoxin concentration is narrow. Immunoassays are routinely used for therapeutic drug monitoring (TDM) of digoxin. The antibody with cross-reactivity to metabolites of digoxin (digoxigenin bis and monodigitoxosides, digox...
متن کاملOPEN ACCESS Jacobs Journal of Nanomedicine and Nanotechnology Establishment of a Highly Specific Enzyme Immunoassay for Digoxin in Human Serum
We previously developed a radioimmunoassay for digoxin using an antiserum raised against digoxin 3’-hemisuccinate -bovine serum albumin. In the present study, we aimed to establish an enzyme immunoassay (EIA) for measuring serum digoxin level in patients, using digoxin 3’-hemisuccinate-β-D-galactosidase as an enzyme-labeled antigen. The developed enzyme immunoassay showed a quantification range...
متن کاملAssessment of Abnormal Serum Digoxin Concentration
ABSTRACT Cardiac glycosides have been used in the management of heart failure for more than 200 years and remain the only drug currently available for Long-term ambulatory use that have positive inotropic effect. The relatively narrow therapeutic- index of cardiac glycosides renders them particularly difficult to use, and the clinician should have a detailed understanding of the actions and ph...
متن کاملInspection of Digoxin level in cardiac heart failure patients refer to Taemin Ejtemai and Shohadaye Ashaer clinic
Background: Heart failure is one of the common cardiovascular diseases and digoxin has the positive effect on it. But unfortunately in spite of its positive effect on heart failure therapeutic and toxic level of it in patients is different and close to each other. The aim of this research was determination of digoxin serum level in failur heart patients. Materials and methods: In this cros...
متن کاملSensitive radioimmunoassay for digoxin in plasma and urine.
A reproducible and sensitive radioimmunoassay for digoxin in either serum, plasma or urine is described. Using 0.5 ml of serum or plasma, the assay sensitivity is 0.05 ng of digoxin/ml. The antiserum and tracer solutions employed are available in a kit sold in the United States. All other reagents were prepared in the laboratory. The assay allows measurement of digoxin in plasma or serum for 96...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biological & pharmaceutical bulletin
دوره 25 4 شماره
صفحات -
تاریخ انتشار 2002