High-Speed Multi-Line OH Planar Laser-Induced Fluorescence in Unsteady Flames
نویسندگان
چکیده
We describe the further development and application of a dual-injection-seeded optical parametric oscillator and associated kHz-rate burst-mode pump laser for high-speed OH planar laser-induced fluorescence in unsteady flames. A detailed overview of the novel double-pulse configuration of the burst-mode laser is given, indicating the potential for use in systems where both high energy and high repetition rate are necessary. Dual-wavelength injection-seeded operation of the optical parametric oscillator is demonstrated and preliminary OH PLIF line switching in a well-characterized natural-gas/air laminar diffusion flame is presented. Applications to high-speed nearly-instantaneous background capture for the elimination of laser scatter and background contamination from polycyclic aromatic hydrocarbons in fuel-rich hydrocarbon flames are also discussed and preliminary data are shown. Lastly, the potential for high-speed two-line planar OH thermometry is described including advantages of utilizing the burst-mode laser and multi-wavelength OPO for simplifying high-speed experimental systems.
منابع مشابه
Simultaneous high-speed measurement of temperature and lifetime-corrected OH laser-induced fluorescence in unsteady flames.
A means of performing simultaneous, high-speed measurements of temperature and OH lifetime-corrected laser-induced fluorescence (LIF) for tracking unsteady flames has been developed and demonstrated. The system uses the frequency-doubled and frequency-tripled output beams of an 80 MHz mode-locked Ti:sapphire laser to achieve ultrashort laser pulses (order 2 ps) for Rayleigh-scattering thermomet...
متن کاملUltrahigh-frame-rate OH fluorescence imaging in turbulent flames using a burst-mode optical parametric oscillator.
Burst-mode planar laser-induced fluorescence (PLIF) imaging of the OH radical is demonstrated in laminar and turbulent hydrogen-air diffusion flames with pulse repetition rates up to 50 kHz. Nearly 1 mJ/pulse at 313.526 nm is used to probe the OH P(2)(10) rotational transition in the (0,0) band of the A-X system. The UV radiation is generated by a high-speed-tunable, injection-seeded optical pa...
متن کاملLaser-induced fluorescence study of OH in flat flames of 1-10 bar compared with resonance CARS experiments.
Laser-induced fluorescence (LIF) measurements of OH were performed in flat stoichiometric CH(4)/air flames burning at 1, 3, 5, 7, and 9.6 bar, which had previously been investigated using OH resonance CARS. In the LIF study, line shape information and temperatures were extracted from excitation spectra; in addition, OH profiles as a function of height above the burner surface and an estimate of...
متن کاملSpatially resolved heat release rate measurements in turbulent premixed flames
Heat release rate is a fundamental property of great importance for the theoretical and experimental elucidation of unsteady flame behaviors such as combustion noise, combustion instabilities, and pulsed combustion. Investigations of such thermoacoustic interactions require a reliable indicator of heat release rate capable of resolving spatial structures in turbulent flames. Traditionally, heat...
متن کاملTwo-dimensional imaging of soot volume fraction and OH in turbulent jet diffusion flames spanning low to high mixing rates
Simultaneous planar measurements of laser-induced incandescence (LII) and Laser-Induced Fluorescence of OH radical were carried out in turbulent jet flames from a simple jet, precessing jet and bluff body burner firing natural gas. These flames span a wide range of global mixing rates and sooting characteristics, and are selected because measurements of total NOx emissions, radiant fraction and...
متن کامل