Determination of uric acid on continuous-flow (AutoAnalyzer II and SMA) systems with a uricase/phenol/4-aminophenazone color test.
نویسندگان
چکیده
This report describes a new specific colorimetric procedure for uric acid assay with AutoAnalyzer II and SMA (Technicon) systems, made specific by the application of uricase. Hydrogen preroxide, formed in this reaction, effects the oxidative coupling of 4-aminophenazone and 2,4-dichlorophenol under the catalytic influence of peroxidase. The red dye formed is measured at 505 or 520 nm. A sample blank measurement is not necessary, and the reagents show very good stability. The test shows linearity up to 714 mumol of uric acid per liter. Results of thie method correlate very well with those by the uricase-ultraviolet and uricase--catalase methods. There is no interference by hemoglobin, bilirubin, lipemia, and various drugs, except a minor interference by alpha-methyldopa. Interference from ascorbate is eliminated by ascorbate oxidase. This method can be regarded as a considerably improved routine test for uric acid on continuous-flow systems in clinical laboratories as compared with the commonly used phosphotungstate method.
منابع مشابه
Immobilized-enzyme nylon-tube reactor for routine determination of uric acid in serum.
We report here the preparation of an immobilized-enzyme nylon-tube reactor containing uricase (EC 1.7.3.3) and the assembly of a flow-through system (Technicon AutoAnalyzer II) for the routine determination of uric acid in serum. Results of these uric acid analyses by use of immobilized uricase, in conjunction with peroxidase (EC 1.11.1.7) and aminophenazone-dichlorophenol in solution, are comp...
متن کاملSimplified automated method for determination of urinary or serum uric acid, based on reduction of ferric-phenanthroline complex.
We describe an automated colorimetric method for determination of uric acid in serum or urine by use of an AutoAnalyzer II or SMA 12/60 (Technicon Corp.). The method depends on reduction of a ferric-phenanthrolirle complex by uric acid under acidic conditions to a ferrous-phenanthroline complex, which absorbs at 505 nm. Advantages of this method over other methods now in use are that color and ...
متن کاملThe use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid.
We describe the use of immobilized enzymes in assay methods for the determination of glucose with glucose oxidase, uric acid with uricase, and urea with urease in serum samples. The enzyme reactor tubes were adapted to continuous-flow analyzers (Technicon AA II, SMA 12/60, and SMAC) used in routine laboratory determinations, and results with their use were compared to those from assays involvin...
متن کاملA new automated uric acid assay.
Currently, the most popular automated method for the determination of serum uric acid is the automated method modified by Musser and Ortigoza (1966) for the TechniconS AutoAnalyzer system. While this method is considered reliable, it suffers from the following deficiencies: (a) it shows non-linearity with dilutions of aqueous uric acid standards and is thus dependent on costly reference sera as...
متن کاملImmobilized uricase for automated assay of uric acid in serum
The wide use of bound enzyme coils with hexokinase and glucose-6-phosphate dehydrogenase in automated analysis for serum-glucose assay [1, 2-] demonstrates the potential of open tubular heterogeneous enzyme reactors [3] in clinical analysis. Such reactors have also been prepared with other enzymes I-4, 5] and in this paper the authors describe a continuous-flow method for uric acid assay with i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 2 شماره
صفحات -
تاریخ انتشار 1978