Positron emission tomography with 11C CGP-12177 to assess beta-adrenergic receptor concentration in idiopathic dilated cardiomyopathy.
نویسندگان
چکیده
BACKGROUND Positron emission tomography (PET) with 11C-labeled CGP-12177 (CGP) has been shown to have the potential to noninvasively measure beta-adrenergic receptor concentration in dog heart. The present study was undertaken to evaluate the clinical value of this technique. METHODS AND RESULTS Eight normal subjects and 10 patients with heart failure related to an idiopathic cardiomyopathy were studied. Estimation of beta-receptor concentration was based on a graphic method applied on myocardial PET time-concentration curves obtained after an intravenous injection of 11C-CGP followed 30 minutes later by a coinjection of labeled and unlabeled CGP. The clinical tolerance of these injections was good. Left ventricular concentration of beta-receptors was decreased in patients compared with controls (3.12 +/- 0.51 versus 6.60 +/- 1.18 pmol/mL, respectively; p < 0.001). This 53% decrease agrees with previous in vitro data. In eight of the 10 patients, the beta-receptor concentration obtained from PET was compared with the beta-receptor density determined on left ventricular endomyocardial biopsy samples by in vitro binding technique using 3H-CGP-12177. Results obtained with both techniques were correlated (r = 0.79, p = 0.019). Moreover, decreased beta-receptor concentration correlated with the beta-contractile responsiveness to intracoronary dobutamine infusion (r = 0.83, p = 0.003), indicating a direct link between changes in the receptor number and its biological function. CONCLUSIONS PET appears to be a safe and reliable method of assessing in vivo changes in the number of left ventricular beta-adrenergic receptor sites of patients with idiopathic cardiomyopathy.
منابع مشابه
Myocardial presynaptic and postsynaptic autonomic dysfunction in hypertrophic cardiomyopathy.
Although hypertrophic cardiomyopathy (HCM) is genetically determined, several other factors, including autonomic dysfunction, may play a role in the phenotypic expression. A recent study using positron emission tomography with [11C]CGP 12177 ([11C]CGP) demonstrated that beta-adrenoceptor (betaAR) density is reduced in HCM and is correlated with disease progression. This present study tested the...
متن کاملAbnormalities of Cardiac Sympathetic Innervation in Arrhythmogenic Right Ventricular Cardiomyopathy Quantitative Assessment of Presynaptic Norepinephrine Reuptake and Postsynaptic b-Adrenergic Receptor Density With Positron Emission Tomography
Background—The frequent provocation of ventricular tachycardia by stress or catecholamines and the efficacy of antiarrhythmic drugs with antiadrenergic properties suggest an involvement of the cardiac adrenergic system in arrhythmogenesis in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). Previous studies demonstrated abnormalities of the presynaptic uptake-1 assessed by I...
متن کاملAbnormal myocardial presynaptic norepinephrine recycling in patients with Brugada syndrome.
BACKGROUND Life-threatening ventricular tachyarrhythmias can occur in young patients without structural heart disease (idiopathic forms). In many patients, these are typically triggered by an increased sympathetic tone, eg, by physical or mental stress. In contrast, in Brugada syndrome, ventricular tachyarrhythmias more often occur during rest or sleep when the vagal tone is predominant. Furthe...
متن کاملReduced beta adrenoceptor density in vivo in human lung tumours: a preliminary study with positron emission tomography.
BACKGROUND Reduced beta adrenergic receptor density in tumours has been reported in previous in vitro studies. The aim of the present study was to assess whether this occurs in vivo. METHODS Pulmonary beta adrenoceptors were imaged and quantified in vivo using positron emission tomography (PET) and the beta antagonist radioligand (S)-[11C]CGP-12177 in five men with lung tumours of mean age 58...
متن کاملMyocardial beta-adrenergic receptor density assessed by 11C-CGP12177 PET predicts improvement of cardiac function after carvedilol treatment in patients with idiopathic dilated cardiomyopathy.
UNLABELLED We evaluated whether myocardial beta-adrenergic receptor (beta-AR) density, as determined by 11C-CGP12177 PET, could predict improvement of cardiac function by beta-blocker carvedilol treatment in patients with idiopathic dilated cardiomyopathy (IDC). METHODS Ten patients with IDC (left ventricular ejection fraction [LVEF]<45%) were studied. Myocardial beta-AR density was estimated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 87 4 شماره
صفحات -
تاریخ انتشار 1993