Evaluation of the clinical performance of an automated procalcitonin assay for the quantitative detection of bloodstream infection.
نویسندگان
چکیده
BACKGROUND Bloodstream infection (BSI) is associated with a high mortality rate. Since the origin of infection is demonstrated in approximately 2/3rds of cases, early and established biomarkers are warranted. We evaluated the clinical performances of automated procalcitonin (PCT) and C-reactive protein (CRP) assays for the quantitative detection of BSI. Analytical performance of the VIDAS(R) BRAHMS PCT assay (bioMérieux, France) was assessed and also compared with the semi-quantitative PCT-Q test (BRAHMS Aktiengesellschaft, Germany). METHODS We prospectively included consecutive patients divided into 3 groups at the Dong-A University Medical Center. Patients were categorized according to the criteria of the American College of Chest Physicians/Society of Critical Care Medicine Consensus Conference (ACCP/SCCM), and also on the basis of catheter-associated bacteremia. RESULTS A total 77 patients were enrolled. All mean values of PCT and PCT-Q were consistent with the reference value. Measured PCT concentrations showed good linearity (r=0.983). The between-run, within-run, and total imprecisions were below 5%. The PCT levels in gram-negative bacteremia were significantly higher than those in gram-positive bacteremia. Furthermore, the PCT concentrations were significantly different among non-infection, bacteremia, sepsis, severe sepsis, and septic shock groups. Our study showed that PCT >0.3 ng/mL had 95.0% sensitivity and 97.3% specificity, whereas CRP >5.46 mg/dL had 85.0% sensitivity and 86.5% specificity for diagnosing sepsis. CONCLUSIONS We suggest that, compared with CRP, PCT is a better diagnostic and discriminative biomarker of sepsis categorized according to the ACCP/SCCM. Moreover, catheter-associated bacteremia could be discriminated from sepsis using PCT concentration.
منابع مشابه
The Comparison of the Point-of-Care Serum Procalcitonin Assay Method with the BRAHMS Certified Method
Background and Aims: As a method for the diagnosis and management of sepsis, the serum procalcitonin assay is routinely used, especially in the emergency department (ED) and intensive care units (ICU). Procalcitonin has reasonable diagnostic accuracy for bacteremia in hospitalized patients of all age groups with suspected infection or sepsis. This study aimed to compare the Getein Biotech proca...
متن کاملProcalcitonin: A Reliable Marker for the Diagnosis of Neonatal Sepsis
Objective(s) In the last few years, serum procalcitonin has been proposed as an early marker of infections in neonates, with varying results. In this study, we aimed to investigate the value of procalcitonin, and C- reactive protein in establishing the diagnosis of neonatal sepsis. Materials and Methods Blood samples were collected at admission from 69 neonates with suspected infection (admi...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملThe Evaluation of Serum Procalcitonin Levels in Neonatal Infections
Background Procalcitonin is known as one of the bacteremia and sepsis markers such as cytokines, interleukin and reactive proteins. This study was conducted to determine the procalcitonin levels in neonatal sepsis. Materials and Methods In a cross-sectional study, the serum procalcitonin levels in 50 term newborns with suspected sepsis was compared with 50 healthy newborns in Ghaem Hospital, Ma...
متن کاملQuality Control Planning of a Hepatitis B Viral Load Laboratory-Developed Assay
Background and Objectives: HBV DNA monitoring is important in management of chronic viral hepatitis B infection. HBV DNA measurements are carried out over period of months to years. So the analytical system must be stable and reproducible. The aim of this study was to determine the performance characteristics and to plan a statistical quality control system of a laboratory-developed real-tim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Korean journal of laboratory medicine
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2010