Application of Non-invasive Microsensing System to Simultaneously Measure Both H+ and O2 Fluxes Around the Pollen Tube
نویسندگان
چکیده
Various ionic and molecular activities in the extracellular environment are vital to plant cell physiological processes. A noninvasive microsensing system (NMS) based on either the scanning ion-selective electrode technique (SIET) or the scanning polarographic electrode technique (SPET) is able to obtain information regarding the transportation of various ions/molecules in intact samples under normal physiological conditions. The two-probe simultaneous test system (2STS) is an integrated system composed of SIET, SPET, and a Xu-Kunkel sampling protocol. In the present study, 2STS was able to simultaneously measure fluxes of H+ and O2 of the lily (Lilium longiflorum Thunb. cv. Ace) pollen tube while avoiding interference between the two probes. The results indicate that the proton fluxes were effluxes, whereas the oxygen fluxes were influxes, and they were closely correlated to each other surrounding the constitutive alkaline band region. Specifically, when the proton effluxes increased, the oxygen influxes also increased. Therefore, the hypothesis of condensed active mitochondria existing in the alkalized area of the pollen tube proposed by Hepler’s group is supported.
منابع مشابه
The strategic use of Good buffers to measure proton gradients around growing pollen tubes
The use of non-invasive vibrating probes for studying proton and bicarbonate flux into and out of cells depends on a knowledge and measurement of local pH. Without buffer the pH surrounding a living cellular system is constantly changing based on the active secretion of protons as well as bicarbonate. Stability of the experimental arena is most easily accomplished if there is a functional buffe...
متن کاملChloride fluxes in lily pollen tubes: a critical reevaluation.
Microelectrodes, made from a Cl(-)-selective liquid ion exchanger previously used to measure putative Cl- fluxes in Lilium longiflorum pollen tubes, were characterized. The electrodes were poorly selective, possessing only about 10-fold selectivity for Cl- over other anions tested. They had only 2.4-fold selectivity for Cl- over the anionic form of the H+ buffer, MES, indicating that the electr...
متن کاملSelf-incompatibility in the Iranian Almond Cultivar ‘Mamaei’ Using Pollen Tube Growth, Fruit Set and PCR Technique
Self-incompatibility has been studied by using controlled pollination, pollen tube growth and PCR methods in the Iranian almond ‘Mamaei.’. Pollen tube growth and fruit set following self and cross-pollination treatments were evaluated. The percentage of initial and final fruit set was determined for each treatment at 30 and 60 days after controlled pollination. Pollen germination and pollen ...
متن کاملEffects of Copper and Leadon Pollen Germination Traits in Almond Cultivars
There is minimal information about the effect of heavy metals such as lead and copper on pollen grains and pollen tubes of fruit trees. Fruit set of these plants are affected by different environmental, biological, physical and chemical factors. If one of these factors be abnormal, pollination, fertilization and fruit set and orchard yield will decrease. In polluted cities, this phenomenon is a...
متن کاملPulsatile influxes of H+, K+ and Ca2+ lag growth pulses of Lilium longiflorum pollen tubes.
Fluxes of H+, K+ and Ca2+ were measured with self-referencing ion-selective probes, near the plasma membrane of growing Lilium longiflorum pollen tubes. Measurements from three regions around short, steady-growing tubes showed small, steady influx of H+ over the distal 40 microm and a region of the tube within 50-100 microm of the grain with larger magnitude efflux from the grain. K+ fluxes wer...
متن کامل