A new method for determination of halogenated flame retardants in human milk using solid-phase extraction.

نویسندگان

  • Cathrine Thomsen
  • Henriette Leknes
  • Elsa Lundanes
  • Georg Becher
چکیده

A method has been developed for quantitation of a selection of halogenated flame retardants in human milk. The method has been validated for seven polybrominated diphenyl ethers (PBDEs), BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, and BDE-183, and the halogenated phenols 2,4,6-tribromophenol (TriBP), pentabromophenol (PeBP), tetrachlorobisphenol-A (TCBP-A), and tetrabromobisphenol-A (TBBP-A). The sample preparation includes solid-phase extraction using an N-vinylpyrrolidone-divinylbenzene copolymer with on-column lipid decomposition followed by additional cleanup on sulfuric acid-silica columns and methylation of the phenolic compounds. Separation and detection were performed by gas chromatography-electron capture mass spectrometry, using a 5% phenyl 95% dimethylpolysiloxane column. The method has been validated in the range of 1.8-180 pg/g milk for most of the halogenated flame retardants. The average absolute recoveries were from 49 to 83%, and the average recoveries with respect to internal standards were in the range of 53 to 121%. Estimated limits of detection were in the range of 0.3 to 1.0 pg/g milk using a sample size of 5 g for all compounds, except TCBP-A, for which the limit of detection was estimated to 6.7 pg/g milk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples

A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...

متن کامل

HCl- Etched Steel Fiber for Determination of Phthalates in Water Samples by Solid-Phase Microextraction

In the present work, a stainless steel wire was etched by hydrochloric acid during a chemical etching process. The obtained black layer on the surface of the fiber was used as sorbent for extraction of trace amount of phthalates in the aqueous samples by solid phase microextraction. New fiber efficiency was investigated using a home-made solid-phase microextraction (SPME) device and gas chr...

متن کامل

Determination of trace amounts of chromium ions in water and food samples using ligand-less solid phase extraction-based modified nano-boehmite(AlOOH)

Chromium is one of the hazardous pollutants in industrial effluents. In this study, a new nano-boehmite modified with sodium dodecyl sulphate is developed for preconcentration trace amounts of chromium ions as a prior step to its determination by flame atomic absorption spectrometry. We investigated the effect of various parameters on the recovery of the analyte ions, including pH of sample solut...

متن کامل

Optimization and development of analytical methods for the determination of new brominated flame retardants and polybrominated diphenyl ethers in sediments and suspended particulate matter

With more stringent legislation on brominated flame retardants, it is expected that increasing amounts of substitutes would replace polybrominated diphenylethers (PBDEs). Therefore, the development and optimization of analytical methodologies that allow their identification and quantification are of paramount relevance. This work describes the optimization of an analytical procedure to determin...

متن کامل

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2002