Dynamic geometry and wall thickness of the aortic neck of abdominal aortic aneurysms with intravascular ultrasonography.
نویسندگان
چکیده
BACKGROUND It is commonly assumed that the aortic wall deforms uniformly and has uniform wall thickness about the circumference. The purpose of this study was to evaluate the aortic wall motion and thickness in the infrarenal aortic neck of patients with abdominal aortic aneurysms who were undergoing endovascular repair (EVAR) and to compare the dynamic measurements of intravascular ultrasonography with the static measurements of computed tomographic angiography (CTA). METHODS A total of 25 patients were evaluated before surgery with CTA and three-dimensional reconstructions on a Vitrea workstation, followed by intraoperative assessment of the proximal aortic neck with intravascular ultrasonography (IVUS) before EVAR. Infrarenal aortic neck dimensions on CTA were obtained at 1-mm intervals, but for the purposes of this study all dimensions on CTA were obtained 1 cm below the lowest renal artery. IVUS analysis of the proximal aortic neck was obtained with a 10-second recorded data loop of aortic wall motion. A Digital Imaging and Communications in Medicine viewer was used to view the recorded loop of aortic movement, and each image was captured and then evaluated with a SCION PCI Frame Grabber to determine aortic dimensions and wall thickness. IVUS diameters (250 measurements of each aorta) were recorded through a full continuous cardiac cycle from the epicenter of the lumen (maintaining the left renal vein in its normal anatomic configuration) in an anteroposterior (AP) direction in the area of greatest wall movement and 90 degrees perpendicular to this direction (lateral movement). RESULTS There was significant variation in infrarenal aortic wall movement about the circumference, with 1.7 +/- 0.6 mm (range, 0.6-2.7 mm) displacement in the AP direction and 0.9 +/- 0.5 mm (range, 0.3-1.5 mm) displacement in the lateral direction (P < .001). Aortic wall thickness was greater in the region of increased AP wall motion than in the area of lesser lateral wall motion (2.3 +/- 0.6 mm vs 1.2 +/- 0.3 mm; P < .001). There was no difference between the IVUS and CTA aortic neck measurements (25.5 vs 25.6 mm; not significant) during the midpoint of the cardiac cycle of IVUS. However, at peak systole, IVUS recorded a greater diameter than CTA (26.4 vs 25.6 mm; P < .001), and at end-diastole, IVUS recorded a smaller diameter than CTA (24.7 vs 25.6 mm; P = .01). CONCLUSIONS The infrarenal neck of aortic aneurysms deforms anisotropically during the cardiac cycle. The greatest displacement is in the AP direction and corresponds with a significantly greater wall thickness in this area. The magnitude of cyclic change in aortic diameter can be as high as 11%. Further evaluation of proximal aortic neck wall motion after EVAR is warranted to determine the interaction of various stent designs and the aortic wall.
منابع مشابه
Drug Therapy for Small Abdominal Aortic Aneurysm
Dear Editor,Abdominal aortic aneurysm is often asymptomatic, less recognized, and causes considerable mortality and morbidity, if missed. The incidence varies from country to country and the occurrence is influenced by modifiable (smoking, coronary heart disease, hypertension, dyslipidemia, and prolonged steroid therapy) and non-modifiable risk factors (increasing age, male gender, and positive...
متن کاملAn Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملManagement of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report
Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75–years-o...
متن کاملFrequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019
Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR. Materials and methods: In this cross-sectional study, medical records were reviewed...
متن کاملImportance of initial aortic properties on the evolving regional anisotropy, stiffness and wall thickness of human abdominal aortic aneurysms.
Complementary advances in medical imaging, vascular biology and biomechanics promise to enable computational modelling of abdominal aortic aneurysms to play increasingly important roles in clinical decision processes. Using a finite-element-based growth and remodelling model of evolving aneurysm geometry and material properties, we show that regional variations in material anisotropy, stiffness...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular surgery
دوره 46 5 شماره
صفحات -
تاریخ انتشار 2007