Sliding Mode Control of DSTATCOM Using Seven Level Multilevel Inverter

نویسندگان

  • VUYYURU SWAPNA
  • ASWANI KUMAR EEDARA
چکیده

In distribution system (DS), the majority of power consumption has been drawn in reactive loads. These loads are drawn in low power factor and therefore give rise to reactive power burden in the distribution system. So that DSTATCOM controller is used to compensate reactive power, correction of power factor and elimination of current harmonics. This paper presence the 7-Level Cascaded Hbridge Inverter as DSTATCOM for compensation of Balanced and Unbalanced Linear and Non-Linear Loads by using Level Shifted and Phase Shifted PWM techniques. The advantage of CHB Inverter is reducing the number of switches and thus switching losses.The simulation verification of the derived results are provided through a three-phase distribution static compensator (DSTATCOM) model. The application in the three-phase system has been shown through simulation studies

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Analysis of Cascaded Multilevel Inverter Based DSTATCOM

In this paper, a single-phase Seven-Level and Five-Level cascaded H-Bridge Inverter (CHB) based Distribution Static Compensator (DSTATCOM) is presented. A simple control algorithm based on inverse park PLL was proposed for both five-level and seven-level inverters. Synchronous Reference Frame theory (SRF) as control algorithm is used for reference source current extraction and to generate gatin...

متن کامل

Performance Investigation of Asymmetrical Cascaded H-Bridge Multilevel Inverter Based DSTATCOM in Distribution Network

This paper presents the performance analysis of asymmetrical cascaded H-bridge multilevel inverter based DSTATCOM in the distribution network. For this, seven level asymmetrical cascaded inverter based DSTATCOM is proposed for the compensation of 11 kV distribution network. The paper also presents the comparative analysis for different asymmetric inverters. For this, 7,9,11 and 13 levels with u...

متن کامل

Design and Simulation of Level Shifted Cascaded H - Bridge Multilevel Inverter Based DSTATCOM

This paper presents an investigation of five-Level Cascaded H – bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) in Power System (PS) for compensation of reactive power and harmonics. The advantages of CHB inverter are low harmonic distortion, reduced number of switches and suppression of switching losses.The DSTATCOM helps to improve the power factor and eliminate the Total ...

متن کامل

Dstatcom Based Five-level Cascade H-bridge Multilevel Inverter for Power Quality Improvement

Power electronic device, nonlinear and unbalanced loads have given rise to power quality problem in distribution systems. Due to factors like competitive generation patterns in a deregulated electric grid and an increasing level of sensitive end user devices, it has become necessary to ensure both reliable and power quality to the end customer. One way to betterment the power quality is using a...

متن کامل

Comprehensive Analysis of LCL Filter Interfaced Cascaded H-Bridge Multilevel Inverter-Based DSTATCOM

Abstract: Three-phase two-level voltage source converters are used for distribution static compensator (DSTATCOM) applications and can be replaced by a multilevel inverter. In this paper, an LCL filter interfaced cascaded H-bridge multilevel inverter-based (CHBMLI) DSTATCOM is simulated and its performance is analyzed considering the system parameters. The analysis considers factors including t...