Validation of automatic measurement of QT interval variability
نویسندگان
چکیده
BACKGROUND Increased variability of beat-to-beat QT-interval durations on the electrocardiogram (ECG) has been associated with increased risk for fatal and non-fatal cardiac events. However, techniques for the measurement of QT variability (QTV) have not been validated since a gold standard is not available. In this study, we propose a validation method and illustrate its use for the validation of two automatic QTV measurement techniques. METHODS Our method generates artificial standard 12-lead ECGs based on the averaged P-QRS-T complexes from a variety of existing ECG signals, with simulated intrinsic (QT interval) and extrinsic (noise, baseline wander, signal length) variations. We quantified QTV by a commonly used measure, short-term QT variability (STV). Using 28,800 simulated ECGs, we assessed the performance of a conventional QTV measurement algorithm, resembling a manual QTV measurement approach, and a more advanced algorithm based on fiducial segment averaging (FSA). RESULTS The results for the conventional algorithm show considerable median absolute differences between the simulated and estimated STV. For the highest noise level, median differences were 4-6 ms in the absence of QTV. Increasing signal length generally yields more accurate STV estimates, but the difference in performance between 30 or 60 beats is small. The FSA algorithm proved to be very accurate, with most median absolute differences less than 0.5 ms, even for the highest levels of disturbance. CONCLUSIONS Artificially constructed ECGs with a variety of disturbances allow validation of QTV measurement procedures. The FSA algorithm provides highly accurate STV estimates under varying signal conditions, and performs much better than traditional beat-by-beat analysis. The fully automatic operation of the FSA algorithm enables STV measurement in large sets of ECGs.
منابع مشابه
QT interval measurement: evaluation of automatic QTc measurement and new simple method to calculate and interpret corrected QT interval.
BACKGROUND Assessment of repolarization duration is often recommended to avoid administration of QT-prolonging drugs in patients with prolonged QTc interval, a frequent situation in the postoperative period. Bazett QT correction inappropriately increases QTc when heart rate is increased, and the use of the Fridericia formula may avoid a falsely prolonged QTc interval. The authors assessed autom...
متن کاملConventional QT Variability Measurement vs. Template Matching Techniques: Comparison of Performance Using Simulated and Real ECG
Increased beat-to-beat variability in the QT interval (QTV) of ECG has been associated with increased risk for sudden cardiac death, but its measurement is technically challenging and currently not standardized. The aim of this study was to investigate the performance of commonly used beat-to-beat QT interval measurement algorithms. Three different methods (conventional, template stretching and...
متن کاملAccuracy of popular automatic QT Interval algorithms assessed by a 'Gold Standard' and comparison with a Novel method: computer simulation study
BACKGROUND Accurate measurement of the QT interval is very important from a clinical and pharmaceutical drug safety screening perspective. Expert manual measurement is both imprecise and imperfectly reproducible, yet it is used as the reference standard to assess the accuracy of current automatic computer algorithms, which thus produce reproducible but incorrect measurements of the QT interval....
متن کاملReproducibility and automatic measurement of QT dispersion.
This study investigated interobserver (two observers) and intrasubject (two measurements) reproducibility of QT dispersion from abnormal electrocardiograms in patients with previous myocardial infarction, and compared a user-interactive with an automatic measurement system. Standard 12-lead electrocardiograms, recorded at 25 mm.s-1, were randomly chosen from 70 patients following myocardial inf...
متن کاملChanges in the QT interval and its adaptation to rate, assessed with continuous electrocardiographic recordings in patients with ventricular fibrillation, as compared to normal individuals without arrhythmias.
Various QT interval variables and heart rate variability parameters were studied in six patients with ventricular fibrillation but without heart disease and compared with findings in 21 normal persons. QT and QT dispersion (QTd) were measured from conventional 12 lead ECGs: for dynamic QT analysis, QT intervals were automatically measured to the end of the T wave (QTe) on a 24 h ECG recording. ...
متن کامل