Optimization of three dimensional planning dosimetric in breast phantom for match region of supraclavicular and tangential fields.

نویسندگان

  • Allahverdi Mahmoud
  • Nourollahi Somayeh
  • Esfahani Mahbod
  • Aghili Mehdi
  • Changizi Vahid
  • Geraily Ghazale
چکیده

AIM Complex geometry of breast tissue causes perturbation in dose distribution. This problem can beget overdose or under-dose points in match region of three fields. The aim of this study is to create dose homogeneity distribution in match region between tangential and supraclavicular fields (SCF) with Gafchromic external beam therapy (EBT) film. MATERIALS AND METHODS In this study, an anatomical slab phantom was designed with cork lung inhomogeneity and plexiy colored heart part. Conventional and three dimensional (3D) methods were utilized along with Gafchromic EBT film. RESULTS In asymmetric fields (3D method) much better results in match region were observed (i.e., maximum amount overlap area of 0.43 cm(2), overlap depth of 3.55 cm and an average overlap width of 0.75 cm). CONCLUSION This study revealed that EBT film is a proper tool for two dimensional (2D) relative-dose measurements. The study showed difficulties in achieving homogenous dose distribution in match region of tangential and supraclavicular.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

متن کامل

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Evaluation of regional nodes irradiation during breast cancer radiotherapy

Background: The purpose of this study was to evaluate nodal irradiation with conventional three-field's technique. Materials and Methods: Fifty patients with breast cancer were enrolled in this study. Computed tomography scans in the supine treatment position were imported into a treatment planning system. Levels I-III axillary and supraclavicular nodes were identified and their depths to the a...

متن کامل

Estimation of the thyroid secondary cancer risk on the patient of standard breast external beam radiotherapy

Introduction: The purpose of this study was to estimate the secondary cancer risk of thyroid for standard radiotherapy methods which are commonly used for breast cancer patients. Materials and Methods: Sixty-four breast cancer patients (their age range was around 50 years old) who referred to Seyed- Al- Shohada hospital (Isfahan, Iran) were included in this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cancer research and therapeutics

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2013