A simple method to create buttonhole cannulation tracks in a busy hemodialysis unit.

نویسندگان

  • Jennifer M Macrae
  • Davina J Tai
  • Mark Daniw
  • John Lee
چکیده

The preference for fistulae as the hemodialysis access of choice has led to a significant number of accesses that are less than ideal for cannulation. Buttonhole cannulation is ideal for such accesses, but the technique for creation provides major challenges. In 12 patients, buttonhole tunnel tracks were created by leaving the polyurethane catheter of a Clampcath hemodialysis needle indwelling for 10 days after the initial cannulation. After each dialysis the catheter was flushed, and dressed with an antibacterial ointment and gauze. Dialysis was carried out via the catheter during that time. After day 10, the catheter was removed, the tunnel track covered with an antibacterial dressing and the tunnel track was cannulated with a dull buttonhole needle at the next dialysis. Successful buttonhole accesses were created in 11 patients after 10 days, the 12th patient required a single sharp needle cannulation before using dull needles. During the first 2 weeks of dull needle cannulation both pain experienced on cannulation and the difficulty cannulating the access were significantly less than in the classical buttonhole technique (P<0.01). Complications during the follow-up period (6 months-1.5 years) included difficulty cannulating with a dull needle (22) and antibacterial agent induced contact dermatitis (4). There was no episode of sepsis or tunnel track infection. Initial cannulation of the fistula using a Clampcath hemodialysis needle, leaving the polyurethane catheter indwelling for 10 days, is a simple, safe, and effective technique for the creation of buttonhole tunnel tracks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The salvage of aneurysmal fistulae utilizing a modified buttonhole cannulation technique and multiple cannulators.

We describe the St Michael's Hospital (SMH) modified buttonhole (BH) cannulation technique as a method that offers a solution for fistulae with aneurysmal dilatation due to repetitive cannulation in a restricted area. This is a prospective cohort study of 14 chronic hemodialysis (HD) patients with problematic fistulae (marked aneurysmal formation and thinning of the overlying skin, bleeding dur...

متن کامل

Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.

BACKGROUND AND OBJECTIVES The relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, a...

متن کامل

Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.

BACKGROUND The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain. STUDY DESIGN A systematic review of randomized trials and observational studies (case reports, case series, stud...

متن کامل

Formation of Abnormal Fistula on Arteriovenous Fistula in a Patient with Buttonhole Cannulation: A Case Report

Buttonhole cannulation has been suggested as a technique that may lead to a reduction in many complications when compared with other techniques such as rope-ladder cannulation. Despite all above, some complications still continue, which may lead to a dysfunction of the arteriovenous fistula (AVF) and inadequate dialysis, having an impact on the quality of life of the patients or eventually maki...

متن کامل

Original Investigation Effect of Buttonhole Cannulation With a Polycarbonate Peg on In-Center Hemodialysis Fistula Outcomes: A Randomized Controlled Trial

Background: Quality improvement strategies to increase and maintain the numbers of arteriovenous fistulas (AVFs) are a critical drive in enhancing the quality of care of patients receiving treatment with hemodialysis. How the AVF is needled is an important consideration in AVF survival; the ideal cannulation technique has not been established to date. Study Design: Prospective randomized single...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hemodialysis international. International Symposium on Home Hemodialysis

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2009