Automated amidolytic method for determining heparin, a heparinoid, and a low-Mr heparin fragment, based on their anti-Xa activity.
نویسندگان
چکیده
Using the chromogenic substrate S-2222, we have optimized and automated an amidolytic assay for heparin. The assay is based on the detection of anti-Xa activity generated by heparin in plasma. The method is reproducible (intra- and interassay CVs of 2.4 and 3.3%, respectively) and reliable in antithrombin III-deficient plasma. Results of this assay, obtained for plasma samples from patients and volunteers treated with heparin, correlate well (r = 0.899) with those of the test for activated partial thromboplastin time. Upon administration of a low-Mr heparinoid (Org 10172) and heparin fragment ( Kabi 2165), however, the activated partial thromboplastin time failed to detect anticoagulant activity, whereas the chromogenic heparin assay revealed anti-Xa activity. This automated amidolytic assay for heparin is therefore suitable not only for monitoring standard therapy with heparin but also for measuring the activity of recently developed heparin fractions.
منابع مشابه
Heparin-induced thrombocytopenia: studies with a new low molecular weight heparinoid, Org 10172.
Studies were performed to determine the cross-reaction rate of the heparin-dependent antibody with Org 10172, a new low molecular weight heparinoid, and to investigate the effect of Org 10172 on platelet activation induced by the antibody. The plasmas of 17 patients with thrombocytopenia induced by standard heparin were shown, by platelet aggregation studies, to contain the heparin-dependent an...
متن کاملPharmacokinetics and pharmacodynamics of danaparoid during continuous venovenous hemofiltration: a pilot study
BACKGROUND In patients with suspected heparin-induced thrombocytopenia (HIT) who need renal replacement therapy, a nonheparin anticoagulant has to be chosen to prevent thrombosis in the extracorporeal circuit. Danaparoid, a low-molecular-weight heparinoid consisting of heparan sulphate, dermatan sulphate, and chondroitin sulphate, is recommended for systemic anticoagulation in patients with HIT...
متن کاملAnti Xa monitoring during treatment with low molecular weight heparin or danaparoid: inter-assay variability.
If laboratory monitoring of low molecular weight heparin (LMWH) therapy is required the test of choice is the anti Xa activity assay. The relationship between anti Xa results obtained using different techniques is unknown. The aim of the present study was to compare anti Xa results obtained with eight different commercially available anti Xa activity assays (five chromogenic and three clotting ...
متن کاملDevelopment and characterization of an automated assay of effective heparin activity in plasma.
We describe a fully automated assay for determining effective heparin activity in plasma, based on heparin-catalyzed inhibition of Factor Xa (EC 3.4.21.6) by antithrombin III (AT III). Residual Factor Xa is determined kinetically by the Du Pont aca discrete clinical analyzer with a chromogenic substrate and is inversely related to heparin activity. Because the test plasma is the sole source of ...
متن کاملDevelopment of a fluorescent anti-factor Xa assay to monitor unfractionated and low molecular weight heparins.
Fluorogenic assays have many potential advantages over traditional clot-based and chromogenic assays such as the absence of interference from a range of factor deficiencies as well as offering the possibility of assays in platelet rich plasma or whole blood. A fluorogenic anti-factor Xa (anti-FXa) assay has been developed for the determination of unfractionated heparin (UFH), low molecular weig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 6 شماره
صفحات -
تاریخ انتشار 1984