Performance of resistive plate counters with low percen of isobutane tage

نویسنده

  • V. Arena
چکیده

The performance of a new kind of double gap resistive plate counter (RPC) has been studied using cosmic rays. The detector was operated with a mixture containing low percentage of isobutane. A comparison with the behaviour of RPC flowed with standard mixture is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cosmic Ray Studies for the Development of a Test Stand for Resistive Plate Counters

Properties of cosmic ray muons including their flux at sea level and the East-West asymmetry are studied. While these properties have been measured well in previous experiments, it has been beneficial to study cosmic ray as it has led to the optimization of our test stand performance and the development of analysis tools required in later testing of the resistive plate counters.

متن کامل

Resistive plate chambers for time-of-flight measurements

The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps s for minimum ionising particles. Applications to HEP experiments have already taken place and many further applications are under study. In this work, we address the operating principles of such counters along with some present challenges, with emphas...

متن کامل

SF6 quenched gas mixtures for streamer mode operation of RPCs at very low voltages

In the present paper we describe a search for gases that allow to reduce the energy of the electrical discharge produced in Resistive Plate Chambers (RPCs) operated in streamer mode, by reducing both the operating voltage and the released charge. This can be achieved, with current gas mixtures of argon, tetrafluoroethane (TFE) and isobutane, by reducing the total amount of quenching components ...

متن کامل

Evaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters

Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...

متن کامل

Cosmic ray test results on resistive plate chamber for the BESIII experiments

A cosmic ray test system has been built to fully qualify the resistive plate chambers for the MUON system of the BESIII experiment. The setup has been designed to measure detector’s performance and to verify the stability and reliability of the MUON system. The same electronics, similar readout method and data analysis for BESIII MUON system have been used for this station. With this station, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1994