A semi-empirical approach to the geometric progression (GP) fitting approximation in estimating photon buildup factor in soft tissue, water, and dosimetric materials

نویسندگان

  • D. Sardari
  • M. Kurudirek
چکیده

Photon buildup factors for soft tissue, water, and dosimetric materials have been computed in the energy range of 0.2 to 2 MeV using geometric progression (GP) fitting approximation. The results for soft tissue and water have been compared with the values obtained through Monte Carlo code MCNP4C. Data obtained from GP fitting method quite well obey a semi empirical relation which is a function of penetration depth, Compton scattering and energy absorption cross section. With the help of this semi-empirical approximation, buildup factors for gamma and X-rays in soft tissue, water, and dosimetric materials consisting of elements Hydrogen (H), Carbon (C), Nitrogen (N) and Oxygen (O), can be easily estimated in the energy range of 0.2 to 2 MeV up to penetration depths of 10 mfp.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy absorption buildup factors of human organs and tissues at energies and penetration depths relevant for radiotherapy and diagnostics

Energy absorption geometric progression (GP) fitting parameters and the corresponding buildup factors have been computed for human organs and tissues, such as adipose tissue, blood (whole), cortical bone, brain (grey/white matter), breast tissue, eye lens, lung tissue, skeletal muscle, ovary, testis, soft tissue, and soft tissue (4-component), for the photon energy range 0.015-15 MeV and for pe...

متن کامل

Chemical Composition Dependence of Exposure Buildup Factors for Some Biological Materials

Exposure buildup factors for some tissues such as bone compact, Muscle striated, orange articulation wax, red articulation wax, nylon, PMMA and paraffin 2 have been computed using the five parameter geometric progression (GP) fitting method in the energy range of 0.01515.0 MeV, up to the penetration of 40 mean free paths (mfp). The variation of exposure buildup factors for all the selected tiss...

متن کامل

Study on effect of detector type in estimating buildup factor of gamma-rays by monte carlo simulation based on variance reduction

This paper presents the study on the effect of detector type in estimating gamma rays buildup factor. In this regard, the flux buildup factors of gamma rays emitted by an isotropic point 60Co source in mean energy 1.253 MeV was evaluated after passing through the Pb, W, Zn, and Ti sample in thickness of 1-5 cm by MCNPX. Four common detector types in simulation of measurement was defined to esti...

متن کامل

Influence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy

Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...

متن کامل

Dosimetric evaluation of Plastic Water Diagnostic Therapy

High-precision radiotherapy planning and quality assurance require accurate dosimetric and geometric phantom measurements. Phantom design requires materials with mechanical strength and resilience, and dosimetric properties close to those of water over diagnostic and therapeutic ranges. Plastic Water Diagnostic Therapy (PWDT: CIRS, Norfolk, VA) is a phantom material designed for water equivalen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012