OBJECTIVE Three-dimensional ultrasonography (3DUS) has recently become a reality because of advances in ultrasound probes and machine processing ability. We have developed an anthropomorphic phantom of the human loin to assess both the accuracy of 3DUS of the kidney and its potential usefulness for training in ultrasonographically guided percutaneous renal intervention. METHODS The model was built with easily available and inexpensive materials such as agar and latex with known ultrasonographic properties. The accuracy of 2-dimensional ultrasonography (2DUS) and 3DUS was assessed by measuring the dimensions of the pelvicalyceal system (PCS) ultrasonographically (pelvis width and calyx diameters) and then comparing these with measurements obtained at the time of construction. Radiology interventional trainees then punctured the PCS with 2DUS and 4-dimensional ultrasonographic (real-time/time-resolved 3DUS) guidance and reported the phantom's performance. RESULTS The 3-dimensional nature of the model's PCS could be clearly visualized on 2DUS and 3DUS, and the scan characteristics were very similar to those in real life. Measurements using 3DUS proved to be closer to the true dimensions of the model's PCS than those using 2DUS. The mean error percentage for 2DUS measurements was -10.2%, and that for 3DUS was -2.2% (P < 0.0001). Interventional trainees were satisfied with the "tissue feel" and level of difficulty posed on puncturing the phantom. CONCLUSIONS Three-dimensional ultrasonography proved to be more accurate than 2DUS for intrarenal measurements using this in vitro renal model. Three-dimensional ultrasonography has the potential to ease diagnostic renal scanning with the ability to further scrutinize and postprocess the scanned volumes. The model was realistic in its anthropomorphic properties and simulated human tissue during puncture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional color Doppler ultrasonography of the kidney vasculature in normal dogs

Three-dimensional color Doppler ultrasonography is a new technique to evaluate the pattern of blood vessels. This study was performed to assess the feasibility of this method in evaluation of kidney vasculature pattern in dogs. In this paper, visualization of the Renal, Interlobar, Arcuate, and interlobular arteries and veins using 3D color Doppler ultrasonography in dogs is shown and the techn...

متن کامل

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

متن کامل

Evaluation of Normal Ultrasonographic Findings of Kidney in Raiini Goat

Objective- to assess the normal ultrasonographic findings of kidney in the Raiini goat. Design- Experimental study. Animals- 10 female Raiini goats. Procedures- .Necropsy was carried out and Kidneys were measured in length, width, and diameter after fixation in formalin. Ultrasonography was carried out by longitudinal and transversal planes to evaluate all renal structures. Echogenicity and ...

متن کامل

Possibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs

Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...

متن کامل

Survey of polycystic kidney disease and other urinary tract abnormalities using ultrasonography in Persian and Persian related cats in Iran

Ultrasonography is an accurate and accessible method for detecting polycystic kidney disease (PKD), an inherited autosomal dominant disease, and other urinary tract diseases. The present work is a preliminary study of PKD and urinary tract abnormalities using ultrasonography in Persian and other long hair cats in Iran. This study was conducted on 83 cats including 68 Persian cats and 15 Persian...

متن کامل

Is urinary N-acetyl-beta-D-glucosaminidase a marker of urological abnormality in children?

  Abstract   Background: Hydronephrosis is the most common congenital condition that is detected   by prenatal ultrasonography. Moreover, the widespread use of prenatal ultrasonography   results in an increased recognition of fetal hydronephrosis. Prenatal hydronephrosis   is diagnosed at an incidence of 1:100 to 1:500 by ultrasonographic studies. The presence of hydronephrosis is not synonymou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2009