Power Quality Improving with Virtual Flux- Based Voltage Source Line Converter

نویسندگان

  • Antti Tarkiainen
  • Juha Pyrhönen
  • Volker Staudt
  • Jouko Niiranen
چکیده

Antti Tarkiainen Power quality improving with virtual flux-based voltage source line converter Lappeenranta 2005 140 p. Acta Universitatis Lappeenrantaensis 206 Diss. Lappeenranta University of Technology ISBN 952–214–011–2, ISBN 952–214–012–0 (PDF), ISSN 1456–4491 Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable dc-link voltage and power factor and sinusoidal line current. This thesis considers the control of the line converter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter is considered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, and a time-domain method, which is effective in a wider frequency band, are used in harmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the Land the LCL-type line filter is discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

Multi-Stage DC-AC Converter Based on new DC-DC converter for energy conversion

This paper proposes a multi-stage power generation system suitable for renewable energy sources, which is composed of a DC-DC power converter and a three-phase inverter. The DC-DC power converter is a boost converter to convert the output voltage of the DC source into two voltage sources. The DC-DC converter has two switches operates like a continuous conduction mode. The input current of DC-DC...

متن کامل

Virtual Flux Based Direct Power Control on Vienna Rectifier

This paper proposes the virtual flux based direct power control for Vienna rectifier. No need for the input voltage sensors, the current regulation loop and PWM voltage modulation block along with the active and reactive power decoupling are some of the salient advantages of this method that make it suitable for controlling the conventional active rectifiers. However, due to the three-level nat...

متن کامل

Comparative Power Quality Analysis of Different DSTATCOM Topologies

This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...

متن کامل

Harmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005