Usefulness of light emitting diode (LED) fluorescent microscopy as a tool for rapid and effective method for the diagnosis of pulmonary tuberculosis.
نویسندگان
چکیده
BACKGROUND Tuberculosis remains world's leading cause of death from a single infectious agent. Fluorescence microscopy offers well-described benefits, comparing with brightfield microscopy, for the evaluation sputum smear samples for tuberculosis. We evaluated the diagnostic performance of fluorescence microscopy, using novel Light Emitting Diode (LED) technology as an alternative to the conventional fluorescence microscopy by Auramine stain as well as brightfield microscopy by Ziehl-Neelsen (ZN) stain. OBJECTIVES The objective of the study was to see the usefulness of LED fluorescent microscopy in the diagnosis of pulmonary tuberculosis. METHODS This is a prospective study consisted of 150 sputum samples from the patients of NIDCH, Mohakhali. All samples were stained by auramine and ZN stain at BSMMU and culture was done in Lowenstein-Jensen (L-J) media as gold standard at NTRL, Mohakhali. RESULTS In this study total 66 (44%) out of 150 sputum specimens were positive for Mycobacterium Tuberculosis by culture. Sensitivity and specificity documented for the different modalities were 95.38% and 94.11%, respectively, for the LED assessment; 68.18% and 90.47%, respectively, for the CFM assessment; and 56.06% and 97.61%, respectively, for brightfield microscopy by ZN stain. The difference in their case detection rate was statistically significant (chi2=119.38, p<0.001). CONCLUSION Fluorescence Microscopy (FM) is more sensitive than ZN for diagnosis of pulmonary tuberculosis. However, since FM is more sensitive and rapid, using this method (LED) in clinical laboratories with large specimen numbers is recommended.
منابع مشابه
Led Fluorescence Microscopy: Leads the Future of Rapid and Effective Pulmonary Tuberculosis Diagnosis
Early diagnosis and appropriate treatment play an important role in combating the mortality and morbidity caused by Tuberculosis and a rapid, reliable microscopy that can detect acid fast bacilli can be a very useful diagnostic modality. We have evaluated the performance of Light Emitting Diode Fluorescence Microscopy as an alternative to the existing conventional methods in the diagnosis of Pu...
متن کاملLaboratory Diagnosis of Tuberculosis - Latest Diagnostic Tools
Microscopy has been a diagnostic tool for TB for over a century, and still currently the most rapid diagnostic method. Standard light microscopy (LM) and fluorescent microscopy (FM) are common methods. The recent development of light emitting diodes (LED), with the ap‐ propriate fluorescent light output for FM and low power consumption, has led to the devel‐ opment of simple, robust LED FM micr...
متن کاملLight-emitting diode with various sputum smear preparation techniques to diagnose tuberculosis.
SETTING Mawenzi Regional Hospital, northern Tanzania. OBJECTIVE To determine the value of light-emitting diode (LED) microscopy in diagnosing tuberculosis (TB) on bleach-treated and direct sputum smears. DESIGN Sputum samples were collected from patients suspected of pulmonary TB who presented consecutively at the laboratory for smear evaluation between December 2009 and February 2010. Fou...
متن کاملRapid Diagnosis of Pulmonary and Extrapulmonary Tuberculosis in HIV-Infected Patients. Comparison of LED Fluorescent Microscopy and the GeneXpert MTB/RIF Assay in a District Hospital in India
HIV-related tuberculosis is difficult to diagnose and is associated with high morbidity and mortality. Recently, the World Health Organization has endorsed the GeneXpert MTB/RIF (Xpert) assay for the diagnosis of pulmonary tuberculosis in HIV-infected patients from developing countries, but information about the use of Xpert for the diagnosis of extrapulmonary tuberculosis is scarce. In this st...
متن کاملUsefulness of the Paralens™ Fluorescent Microscope Adaptor for the Identification of Mycobacteria in Both Field and Laboratory Settings
The presence of acid-fast bacilli (AFB) in laboratories has traditionally been demonstrated using the fluorochrome method, which requires a fluorescent microscope or the Ziehl-Neelsen (ZN) method employing light microscopy. Low sensitivity of the ZN method and high costs of fluoroscopy make the need for a more effective means of diagnosis a top priority, especially in developing countries where...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bangladesh Medical Research Council bulletin
دوره 37 1 شماره
صفحات -
تاریخ انتشار 2011