Optimization of multiplanar reformations from isotropic data sets acquired with 16-detector row helical CT scanner.

نویسندگان

  • Tracy A Jaffe
  • Rendon C Nelson
  • G Allan Johnson
  • Ellie R Lee
  • Terry T Yoshizumi
  • Carolyn R Lowry
  • Anthony B Bullard
  • David M DeLong
  • Erik K Paulson
چکیده

Institutional review board approval and waiver of consent were obtained for the patient component of this retrospective HIPAA-compliant study. By using an anthropomorphic phantom and metal oxide semiconductor field effect transistor detectors, radiation dose was determined for one eight-detector row and two 16-detector row computed tomographic (CT) protocols. A custom phantom was scanned by using the three protocols to identify isotropy. Contrast-to-noise ratios (CNRs) were determined for the same protocols by using a third phantom. Seven patients had undergone isotropic 16-detector row CT of the abdomen and pelvis. Anonymized coronal reformations at various thicknesses were ranked qualitatively by three radiologists. Effective dose equivalents were similar for the eight- and 16-detector row protocols. When transverse and coronal reformations of data acquired in the custom phantom were compared, coronal reformations obtained with the 16-detector row and 0.625-mm section thickness protocol were found to be nearly identical to the transverse image for all sets of line pairs. CNRs were consistently highest on 5-mm-thick coronal reformations (CNR range, 1.2-3.3). For qualitative assessment, 2- and 3-mm-thick coronal reformations were consistently preferred.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional imaging of thoracic diseases with multi-detector row CT.

The benefits of multi-detector row CT (MDCT) relative to single-detector row helical CT are considerable. Multi-detector row CT allows shorter acquisition times, greater coverage, and superior image resolution. These factors substantially increase the diagnostic accuracy of the examination. Three-dimensional (3D) volume data from MDCT provides various unique applications on thoracic diseases. T...

متن کامل

Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.

PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...

متن کامل

Using multidetector row computed tomography to diagnose and stage pancreatic carcinoma: the problems and the possibilities.

The sensitivity of computed tomography (CT) in the diagnosis of pancreatic neoplasms and accurate tumor staging has significantly been improved by the use of thin-section multi-detector row CT techniques. Greater table speed, improved tube cooling, high resolution imaging and the possibility of isotropic voxels have led to optimal multiplanar reconstruction in any arbitrary plane and particular...

متن کامل

Multidetector row CT angiography in spontaneous lobar intracerebral hemorrhage: a prospective comparison with conventional angiography.

BACKGROUND AND PURPOSE The aim of our study was to assess the accuracy of multidetector row CT angiography (MDCTA) in the detection of the underlying vascular abnormalities causing spontaneous lobar intracerebral hemorrhage (ICH) compared with conventional digital subtraction angiography (DSA). MATERIALS AND METHODS Seventy-eight patients who underwent MDCTA with use of a 16-detector row scan...

متن کامل

Experimental study and optimization of scan parameters that influence radiation dose in temporal bone high-resolution multidetector row CT.

BACKGROUND AND PURPOSE MDCT has some specific scan parameters that may systematically increase or decrease radiation dose to patients. This study explored the scan protocol parameters that impact radiation dose in temporal bone MDCT and determined the optimal scan parameters that balance radiation dose with diagnostic image quality. MATERIALS AND METHODS Using exsomatized cadaveric heads, tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 238 1  شماره 

صفحات  -

تاریخ انتشار 2006