Geometric interpretation of the gamma dose distribution comparison technique: interpolation-free calculation.

نویسندگان

  • Tao Ju
  • Tim Simpson
  • Joseph O Deasy
  • Daniel A Low
چکیده

The gamma dose comparison tool has been used by numerous investigators to quantitatively compare multidimensional dose distributions. The gamma tool requires the specification of dose and distance-to-agreement (DTA) criteria for acceptable variations between the dose distributions. The tool then provides a comparison that simultaneously evaluates the dose difference and distance to agreement of the two dose distributions. One of the weaknesses of the tool is that the comparison requires one of the dose distributions to have a relatively high spatial resolution, with points spaced significantly closer than the DTA criterion. The determination of gamma involves an exhaustive search process, so the computation time is significant if an accurate gamma is desired. The reason for the need for high spatial resolution lies with the fact that the gamma tool measures the closest point in one of the dose distributions (the evaluated distribution) with individual points of the other distribution (the reference distribution) when the two distributions are normalized by the dose difference and DTA criteria for the dose and spatial coordinates, respectively. The closest point in the evaluated distribution to a selected reference distribution point is the value of gamma at that reference point. If individual evaluated dose distribution points are compared, the closest point may not accurately reflect the closest value of the evaluated distribution as if it were interpolated on an infinite resolution grid. Therefore, a reinterpretation of the gamma distribution as the closest geometric distance between the two distributions is proposed. This is conducted by subdividing the evaluated distribution into simplexes; line segments, triangles, and tetrahedra for one, two, and three-dimensional (3D) dose distributions. The closest distance between any point and these simplexes can be straightforwardly computed using matrix multiplication and inversion without the need of interpolating the original evaluated distribution. While an exhaustive search is still required, not having to interpolate the evaluated distribution avoids the drastic growth of calculation time incurred by interpolation and makes the gamma tool more practical and more accurate. In our experiment, the geometric method accurately computes gamma distributions between 3D dose distributions on a 200 x 200 x 50 grid within two minutes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introduction of a Reliable Software for the Calculation of the Gamma Index

Introduction: The gamma index is a known parameter for radiotherapy dose verification. Many free and commercial programs have been written for the calculation of this index. However, the verification of the results has been overlooked in many of the programs. The present study tested the validity of three gamma index calculator programs. Material and ...

متن کامل

معرفی روش جدید ارزیابی گاما وزن داده شده برای مقایسه توزیع دوز به دست آمده از الگوریتمهای محاسباتی دوز با نتایج تجربی در پرتودمانی

Introduction: One of the problems that exists in the quality control procedure of the treatment planning systems and the computer simulation of the radiotherapy or diagnostic radiology validation is comparing the dose distribution resulted from the dose calculation algorithms with the experimental results(as a reference). For this purpose, several methods have been proposed to compare these dos...

متن کامل

Evaluation of semiempirical VMAT dose reconstruction on a patient dataset based on biplanar diode array measurements

We report the results of a preclinical evaluation of recently introduced commercial tools for 3D patient IMRT/VMAT dose reconstruction, the Delta4 Anatomy calculation algorithm. Based on the same initial measurement, volumetric dose can be reconstructed in two ways. Three-dimensional dose on the Delta4 phantom can be obtained by renormalizing the planned dose distribution by the measurement val...

متن کامل

A technique for the quantitative evaluation of dose distributions.

The commissioning of a three-dimensional treatment planning system requires comparisons of measured and calculated dose distributions. Techniques have been developed to facilitate quantitative comparisons, including superimposed isodoses, dose-difference, and distance-to-agreement (DTA) distributions. The criterion for acceptable calculation performance is generally defined as a tolerance of th...

متن کامل

Experimental evaluation of midline dose calculation methods in In vivo dosimetry using anatomic thorax phantom

Background: In vivo dosimetry is a method for estimation of overall error in the delivered dose to the patients at the end of radiotherapy process. In this research, two methods for target dose calculation were evaluated on midline and central axis of photon beams in in vivo dosimetry of thorax fields. Materials and Methods: Entrance and exit doses for anterior and lateral fields of thorax were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2008