SCIENTIFIC CORRESPONDENCE Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry

نویسندگان

  • F A Medeiros
  • R Susanna
چکیده

Aims: To evaluate different algorithms used to analyse retinal nerve fibre layer thickness (RNFL) data obtained by scanning laser polarimetry, in order to compare their relative abilities to discriminate between patients with glaucomatous localised nerve fibre layer defects and normal subjects. Methods: 48 eyes of 48 glaucomatous patients with localised RNFL defects and 53 eyes of 53 healthy subjects were included in this study. The localised RNFL defects were identified by RNFL photography and/or slit lamp biomicroscopic examination. All patients were submitted to RNFL examination using scanning laser polarimetry (GDx nerve fibre analyser, Laser Diagnostic Technologies, Inc, San Diego, CA, USA). Three methods of analysis of polarimetry data were used: GDx software provided parameters; RNFL thickness measurements in 16 equal sectors around the optic disc (sectoral analysis); and Fourier analysis of the curve of distribution of RNFL thickness measurements. Linear discriminant functions were developed to assess sensitivity and specificity of the sectoral based analysis and Fourier analysis and were compared to the GDx parameters. In addition, areas under the receiver operating characteristic (ROC) curves were compared. Results: At a fixed specificity of 91%, the sensitivity of the linear discriminant function from sectoral data (LDF sectoral) was 81%, with an area under the ROC curve of 0.93. The linear discriminant function from Fourier measures had a comparable performance, with an area under the ROC curve of 0.93, and sensitivity of 71% for specificity at 91%. At the same specificity, the sensitivities of the GDx software provided parameters ranged from 15% to 40%. The areas under the ROC curves for the LDF sectoral and LDF Fourier were significantly greater than the ROC curve area for the single best GDx parameter. Conclusion: The sectoral based analysis and the Fourier analysis of RNFL polarimetry data resulted in an improved detection of eyes with glaucomatous localised nerve fibre layer defects compared to the GDx software provided parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry.

AIMS To evaluate different algorithms used to analyse retinal nerve fibre layer thickness (RNFL) data obtained by scanning laser polarimetry, in order to compare their relative abilities to discriminate between patients with glaucomatous localised nerve fibre layer defects and normal subjects. METHODS 48 eyes of 48 glaucomatous patients with localised RNFL defects and 53 eyes of 53 healthy su...

متن کامل

Axonal loss from acute optic neuropathy documented by scanning laser polarimetry.

BACKGROUND/AIMS Retinal nerve fibre layer analysis by scanning laser polarimetry has been shown to facilitate diagnosis of glaucoma while its role in glaucoma follow up is still unclear. A major difficulty is the slow reduction of retinal nerve fibre layer thickness in glaucomatous optic neuropathy. Eyes of patients were studied after acute retrobulbar optic nerve lesion in order to evaluate th...

متن کامل

SCIENTIFIC REPORT Sensitivity and specificity of scanning laser polarimetry using the GDx

Background/aims: To determine the sensitivity and the specificity of the GDx in the detection of (1) advanced glaucoma, (2) early glaucoma, and (3) nerve fibre bundle defects (NFBD). Methods: Group A comprised 20 eyes with reproducible glaucomatous visual field defects confirmed by octopus perimetry, group B consisted of 10 eyes with normal visual fields but either glaucomatous NFBD or deterior...

متن کامل

SCIENTIFIC CORRESPONDENCE Retinal nerve fibre layer loss in patients with type 1 diabetes mellitus without retinopathy

Background/aim: There is evidence suggesting the occurrence of neurovisual abnormalities in patients with diabetes without retinopathy. However, the determination of abnormalities in the neural and glial elements in vivo is difficult. The aim of this study was to investigate whether a retinal nerve fibre layer (RNFL) defect (as determined by scanning laser polarimetry, SLP) is present in patien...

متن کامل

Scanning laser polarimetry of the retinal nerve fibre layer in primary open angle and capsular glaucoma.

AIMS To evaluate the clinical value of scanning laser polarimetry with the nerve fibre analyser type II in primary open angle glaucoma (POAG) and capsular glaucoma. METHODS Scanning laser polarimetry was performed on one eye of 30 patients suffering from POAG, 25 patients suffering from capsular glaucoma, and on 35 healthy control subjects. The retinal nerve fibre layer (RNFL) thickness value...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003