A Classification System for the Spread of Polymethyl Methacrylate in Vertebral Bodies Treated with Vertebral Augmentation

نویسندگان

  • Joseph Frankl
  • Michael P. Sakata
  • Gagandeep Choudhary
  • Seung Hur
  • Andrew Peterson
  • Charles T. Hennemeyer
چکیده

In this study, we develop a classification system for describing polymethyl methacrylate (PMMA) spread in vertebral bodies after kyphoplasty or vertebroplasty for vertebral compression fractures (VCFs) and for assessing whether PMMA spread varies between operators, VCF etiology, or vertebral level. Intraoperative fluoroscopic images of 198 vertebral levels were reviewed in 137 patients (women, 84; men, 53; mean age, 75.8 ± 12.5; and those with a diagnosis of osteoporosis, 63%) treated with kyphoplasty between January 01, 2015 and May 31, 2015 at a single center to create a 5-class descriptive system. PMMA spread patterns in the same images were then classified by 2 board-certified radiologists, and a third board-certified radiologist resolved conflicts. A total of 2 primary PMMA spread patterns were identified, namely, acinar and globular, with subtypes of localized acinar, diffuse globular, and mixed, to describe an equal combination of patterns. Interrater reliability using the system was moderate (κ = 0.47). After resolving conflicts, the most common spread class was globular (n = 63), followed by mixed (n = 58), diffuse globular (n = 30), acinar (n = 27), and localized acinar (n = 20). The spread class after treatment by the 2 most frequent operators differed significantly (n1 = 63, n2 = 70; P < .0001). There was no difference in the spread class between VCF etiologies or vertebral levels. PMMA spread may, therefore, be a modifiable parameter that affects kyphoplasty and vertebroplasty efficacy and adverse events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Vertebral Body Augmentation: An Updated Review

There are many medical conditions like osteoporosis, tumor, or osteonecrosis that weaken the structural strength of the vertebral body and prone it to fracture. Percutaneous vertebral augmentation that is usually applied by polymethylmethacrylate is a relatively safe, effective, and long lasting procedure commonly performed in these situations. In this paper, we updated a review of biomechanics...

متن کامل

Percutaneous Pedicle Screw Fixation with Polymethylmethacrylate Augmentation for the Treatment of Thoracolumbar Intravertebral Pseudoarthrosis Associated with Kummell's Osteonecrosis

Purpose. The purpose of our study is to evaluate the therapeutic efficacy of short-segment percutaneous pedicle screw fixation with polymethylmethacrylate (PMMA) augmentation for the treatment of osteoporotic thoracolumbar compression fracture with osteonecrosis. Methods. Osteoporotic thoracolumbar compression fractures with avascular necrosis were treated by short-segment PPF with PMMA augment...

متن کامل

Pulmonary Embolism with Vertebral Augmentation Procedures

With the prevalence of an aging American population on the rise, osteoporotic vertebral fractures are becoming a common occurrence, resulting in an increase in vertebral augmentation procedures and associated complications such as cement leakage, vertebral compressions, and pulmonary embolism. We describe a patient who presented with respiratory distress three years following kyphoplasty of the...

متن کامل

Adjacent vertebral failure after vertebroplasty. A biomechanical investigation.

Vertebroplasty, which is the percutaneous injection of bone cement into vertebral bodies has recently been used to treat painful osteoporotic compression fractures. Early clinical results have been encouraging, but very little is known about the consequences of augmentation with cement for the adjacent, non-augmented level. We therefore measured the overall failure, strength and structural stif...

متن کامل

Initial clinical experience with a novel vertebral augmentation system for treatment of symptomatic vertebral compression fractures: A case series of 26 consecutive patients

BACKGROUND Minimally invasive vertebral augmentation procedures are widely used to treat vertebral compression fractures although procedural polymethylmethacrylate cement leakage remains common. We report herein our initial experience with a novel vertebral augmentation technique designed to treat symptomatic vertebral osteoporotic fractures and osteolytic metastases with minimal cement extrava...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016