Measurement Uncertainties in Gas-based Monitors for High Repetition Rate X-ray Fel Operations*

نویسندگان

  • Y. Feng
  • J. Krzywinski
  • M. Campell
  • D. W. Schafer
  • E. Ortiz
  • M. Rowen
  • T. O. Raubenheimer
چکیده

Thermodynamic simulations using a finite difference method were carried out to investigate the measurement uncertainties in gas-based X-ray FEL diagnostic monitors under high repetition rate operations such as planned for the future LCLS-II soft and hard X-ray FEL’s. For monitors using relatively high gas pressures for obtaining sufficient signals, the absorbed thermal power becomes non-negligible as repetition rate increases while keeping pulse energy constant. The fluctuations in the absorbed power were shown to induce significant measurements uncertainties, especially in the single-pulse mode. The magnitude of this thermal effect depends nonlinearly on the absorbed power and can be minimized by using a more efficient detection scheme in which the gas pressure can be set sufficiently low.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Experimental Observation of the Gas Filamentation Effect using a Two-bunch X-ray FEL Beam

We report the experimental observation of the filamentation effect in gas devices designed for X-ray Free-electron Laser’s. The measurements were carried out at the Linac Coherent Light Source on the X-ray Correlation Spectroscopy (XCS) instrument using a Two-bunch FEL beam at 6.5 keV with 122.5 ns separation passing through an Argon gas cell. The relative intensities of the two pulses of the T...

متن کامل

Direct experimental observation of the gas density depression effect using a two-bunch X-ray FEL beam

The experimental observation of the depression effect in gas devices designed for X-ray free-electron lasers (FELs) is reported. The measurements were carried out at the Linac Coherent Light Source using a two-bunch FEL beam at 6.5 keV with 122.5 ns separation passing through an argon gas cell. The relative intensities of the two pulses of the two-bunch beam were measured, after and before the ...

متن کامل

Transient thermal stress wave and vibrational analyses of a thin diamond crystal for X-ray free-electron lasers under high-repetition-rate operation.

High-brightness X-ray free-electron lasers (FELs) are perceived as fourth-generation light sources providing unprecedented capabilities for frontier scientific researches in many fields. Thin crystals are important to generate coherent seeds in the self-seeding configuration, provide precise spectral measurements, and split X-ray FEL pulses, etc. In all of these applications a high-intensity X-...

متن کامل

Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors.

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in ...

متن کامل

Laser power meters as an X-ray power diagnostic for LCLS-II

For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016