Evaluation of a new handheld biosensor for point-of-care testing of whole blood beta-hydroxybutyrate concentration.
نویسندگان
چکیده
OBJECTIVES To evaluate performance characteristics of the newly available handheld combined glucose and ketone meter for beta-hydroxybutyrate measurement. DESIGN Laboratory method evaluation. MAIN OUTCOME MEASURES Accuracy of beta-hydroxybutyrate measurement and effect of acetoacetate interference at clinically important beta-hydroxybutyrate levels. RESULTS Deming regression analysis of beta-hydroxybutyrate measurements assessed by the ketone sensor and a laboratory enzymatic method revealed a coefficient of determination of 0.989 (P<0.001). Passing-Bablok regression analysis showed a linear relationship between the two methods, ie Y= -0.32+1.13X. The 95% confidence interval of the slope and y-intercept were: slope=1.13 (95% confidence interval, 1.04 to 1.22); intercept= -0.32 (95% confidence interval, -0.59 to -0.06). The Bland-Altman plot showed a small proportional bias between the two methods. The mean bias +/-2 standard deviations was between -0.53 and 0.67 mmol/L. Beta-hydroxybutyrate measurements made by the sensor were linear up to 6 mmol/L. Replicate analysis of two samples spiked with 3.6 mmol/L and 0.8 mmol/L of beta-hydroxybutyrate resulted in coefficients of variation of 3.3% and 13%, respectively. The presence of acetoacetate caused a negative interference in beta-hydroxybutyrate measurement. Beta-hydroxybutyrate recovery was 97.0% and 90.7% when the ketone body ratios were 6:1 and 3:1, respectively. CONCLUSION The analytical performance of the sensor, when operated according to manufacturer's instructions, could meet the needs of point-of-care beta-hydroxybutyrate measurement. Additional clinical studies are needed to assess the benefits of introducing such an assay in a clinical setting.
منابع مشابه
Point-of-care blood ketone testing: screening for diabetic ketoacidosis at the emergency department.
INTRODUCTION We piloted the use of a blood beta-hydroxybutyrate meter as a point-of-care testing in an emergency department (ED) to establish its role in distinguishing ketosis/ketoacidosis from simple hyperglycaemia, and develop guidelines for its use in the ED. METHODS 111 consecutive patients presenting with capillary glucose levels exceeding 14 mmol/L had a simultaneous blood ketone measu...
متن کاملEvaluation of an electrochemical sensor for measuring blood ketones.
OBJECTIVE To evaluate the performance of a hand-held ketone sensor that is able to measure blood beta-hydroxybutyrate (beta-HBA) concentrations within 30 s in patients with diabetic ketoacidosis (DKA) and patients who attend a weight management clinic. RESEARCH DESIGN AND METHODS Two groups of patients were studied: 19 patients admitted with DKA and 156 patients attending a weight management ...
متن کاملMicrofluidic biosensor for β-Hydroxybutyrate (βHBA) determination of subclinical ketosis diagnosis
BACKGROUND Determination of β-hydroxybutyrate (βHBA) is a gold standard for diagnosis of Subclinical Ketosis (SCK), a common disease in dairy cows that causes significant economic loss. Early detection of SCK can help reduce the risk of the disease progressing into clinical stage, thus minimizing economic losses on dairy cattle. Conventional laboratory methods are time consuming and labor-inten...
متن کاملEvaluation of an electrochemical biosensor for uric acid measurement in human whole blood samples.
BACKGROUND Uric acid measurement has become increasingly important, and electrochemically modified detection method based portable devices hold a dominant position in the market for point of care and self-monitoring of uric acid blood levels. However, there has been a lack of detailed performance evaluation of the electrochemical detection devices that are currently being used in professional h...
متن کاملPoint-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity
Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hong Kong medical journal = Xianggang yi xue za zhi
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2002