Trans-aortic counterpulsation: a viable alternative?

نویسندگان

  • Bharat Datt
  • Lisa Hutchison
  • Charles Peniston
چکیده

Transthoracic intra-aortic balloon pump (IABP) insertion has been a relatively rare and uncommon procedure. However, it is an established beneficial option in patients with severe peripheral vascular disease (PVD) accompanied with bi-lateral femoral arterial occlusion. There are several viable alternatives to trans-aortic IABP insertion, including trans-axillary or in abdominal aorta (requiring a laparotomy). Cardiac surgery has the advantage of an open sternum, facilitating effortless direct intra-aortic balloon (IAB) insertion into the aorta. The IAB can be inserted either through a 9-mm graft or directly into the ascending aorta. During cardiac surgery, direct insertion into the ascending aorta with the balloon tip lying distally in the abdominal aorta is facilitated with an open sternum. The base of the balloon lies approximately 2 cm below the left subclavian and can be confirmed through a trans-esophageal echocardiogram (TEE). Elimination of a graft insertion saves the team from time-consuming maneuvers and additional hemorrhagic complications. In our experience, postoperative vasoplegic syndrome coupled with myocardial edema contributed to patent instability and was treated with vasopressin and transthoracic IAB insertion. The CS 100 (Datascope Corp., Mahwah, NJ) console allowed the ability to time the balloon accurately. This case report details our experience with one such patient and establishes trans-aortic counter-pulsation as a safe and viable option in patients with severe PVD, where percutaneous insertion is precluded or has failed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of aortic counterpulsation to improve sustained coronary artery patency during acute myocardial infarction. Results of a randomized trial. The Randomized IABP Study Group.

BACKGROUND Aortic counterpulsation has been observed to reduce the rate of reocclusion of the infarct-related artery after patency has been restored during acute myocardial infarction in observational studies. To evaluate the benefit-to-risk ratio of aortic counterpulsation during the early phase of myocardial infarction, a multicenter randomized clinical trial was performed. METHODS AND RESU...

متن کامل

Sustained Coronary Artery Patency During Acute Myocardial Infarction Results of a Randomized Trial

Background Aortic counterpulsation has been observed to reduce the rate of reocclusion of the infarct-related artery after patency has been restored during acute myocardial infarction in observational studies. To evaluate the benefit-torisk ratio of aortic counterpulsation during the early phase of myocardial infarction, a multicenter randomized clinical trial was performed. Methods and Results...

متن کامل

Prevention of Possible Embolus Following Intra Aortic Balloon Counterpulsation (IABP) Insertion by Transesophageal Echocardiography ( TEE )

Severe atherosclerosis of the descending aorta is directly related to atheroembolic events. Transesophageal echocardiography (TEE) is a sensitive technique for evaluating such atheroma plaques of the thoracic aorta which may predict the risk of emboli. We describe a patient with severe intraluminal aortic atherosclerotic plaques detected by TEE while positioning an Intraaortic Balloon Counterpu...

متن کامل

[Left ventricular rupture of mitral valve prosthesis implantation treated using an intra-aortic balloon pump counterpulsation].

Left ventricular rupture is an infrequent but potentially fatal complication of mitral valve replacement. In spite of the fact that several methods of repair have previously been described, the mortality rate remains nearly 85%. The use of the intra-aortic balloon pump counterpulsation may increase the possibilities of success in the repair of this dreaded complication. We present here three ca...

متن کامل

Intra-aortic balloon counterpulsation in acute myocardial infarction: too few or too many?

The concept of counterpulsation was introduced over four decades ago by Clauss et al. (1) and adapted to intra-aortic balloon pumping (IABP) by Moulopaulus et al. (2) in 1962, and it remains the most common mode of cardiac assist. Intra-aortic balloon counterpulsation (IABCP) was first introduced into clinical practice by Kantrowitz et al. (3) in 1968 for the treatment of cardiogenic shock. Ini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2007