Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.

نویسندگان

  • Z Liang
  • T G Turkington
  • D R Gilland
  • R J Jaszczak
  • R E Coleman
چکیده

A three-dimensional reconstruction method for simultaneous compensation of attenuation, scatter and distance-dependent detector response for single photon emission computed tomography is described and tested by experimental studies. The method determines the attenuation factors recursively along each projection ray starting at the intersected source voxel closest to the detector. The method substracts the scatter energy window data from the primary energy window data for scatter compensation. The detector response is modelled to be spatially invariant at a constant distance from the detector. The method convolves source distribution with the modelled response function to compensate for the smoothed by use of a non-uniform entropy prior to searching for the maximum a posteriori probability solution. The method was tested using projections acquired from a chest phantom by a three-headed detector system with parallel hole collimators. An improvement was shown in image noise, recognition of object sizes and shapes, and quantification of concentration ratios.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

متن کامل

Collimator-detector response compensation in molecular SPECT reconstruction using STIR framework

Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT.  In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...

متن کامل

Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.

UNLABELLED Attenuation, photon scatter, and distance-dependent collimator-detector response are major degrading factors in myocardial SPECT images. The current study investigated whether compensation for these factors improves perfusion defect detectability, and compared the results for human observers with a previous study using a mathematical observer. METHODS Four methods were investigated...

متن کامل

A model based, anatomy dependent method for ultra-fast creation of primary SPECT projections

  Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...

متن کامل

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1992