Evaluation of X-Ray Beam Quality Based on Measurements and Estimations Using SpekCalc and Ipem78 Models.

نویسندگان

  • Suk Chiang Chen
  • Wei Loong Jong
  • Ahmad Zaky Harun
چکیده

BACKGROUND Different computational methods have been used for the prediction of X-ray spectra and beam quality in diagnostic radiology. The purpose of this study was to compare X-ray beam qualities based on half-value layers (HVLs) determined through measurements and computational model estimations. METHODS The HVL estimations calculated by IPEM78 (Spectrum Processor of the Institute of Physics and Engineering in Medicine's Report 78) and SpekCalc software were compared with those determined through measurements. In this study, the HVLs of both Philips (Phil) (Philips Healthcare, Best, NL) and General Electric Company (GE) (GE Global Research, Niskayuna, US) diagnostic range X-ray machines (50 kVp to 125 kVp) were evaluated. RESULTS In the HVL estimations, SpekCalc and IPEM78 showed maximum differences of 10% and 9%, respectively, compared with direct measurements. Both models provided means and SDs of HVLs that were within 5% of the HVL measurements of GE and Phil machines. CONCLUSION Both computational models provide an alternative method for estimating the HVL of diagnostic range X-ray. These models are user-friendly in predicting HVLs, which are used to characterise the quality of the X-ray beam, and these models provide predictions almost instantly compared with experimental measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes.

A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the particularly wide range of tube potentials (40-300 kVp) and anode angles (recom...

متن کامل

Quality Control of Radiography Equipments in Golestan Province of IRAN

Introduction The main goal of this study was to perform quality control test on all radiography units operating in Golestan province of IRAN. Materials and Methods Forty-four X-ray units were examined based on general accepted programs for quality control. Eight parameters including kVp accuracy, kVp reproducibility, mA-time reciprocity, exposure linearity, exposure reproducibility, timer accur...

متن کامل

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

متن کامل

Evaluation of underwater acoustic propagation model (Ray theory) in a river using Fluvial Acoustic Tomography System

Underwater acoustics is widely used in many applications, such as oceanography, marine biology, hydrography, fishery, etc. Different models are introduced to simulate the underwater acoustic propagation in the oceans and the seas. In this study, the Ray Theory model is used to simulate the acoustic wave propagation in a shallow-freshwater river (Gono River) located in western part of Japan. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Malaysian journal of medical sciences : MJMS

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2012