Radiation therapy planning using a volumetric 3-D display: PerspectaRAD
نویسندگان
چکیده
We describe PerspectaRAD, the first tool for the review and modification of external-beam radiation therapy treatment plans with a volumetric three-dimensional display (Perspecta 1.9, Actuality Medical, Bedford, MA, USA) and a dedicated software application (PerspectaRAD, Actuality Medical). We summarize multi-institution retrospective studies that compare the system’s efficacy to the incumbent 2-D display-based workflow. Contributions include: visualizing the treatment plan in a volumetric 3-D display, modifying the beam locations and performing point-and-click measurement in 3-D with a 3-D physical interface, and simultaneously viewing volumetric projections of the native CT data and isodose contours. The plans are synchronized with the hospital treatment planning system, Pinnacle 3 (Philips Medical, WI, USA). In the largest of five studies, 33 plans were retrospectively randomized and replanned at three institutions, including 12 brain, 10 lung, and 11 abdomen / pelvis. The PerspectaRAD plan was as good as or better than plans created without PerspectaRAD 70% of the time. Radiation overdose regions were more likely to be obvious inside the target volume than when reviewed in the 2-D display alone. However, the planning time was longer with PerspectaRAD. The data demonstrate that PerspectaRAD facilitates the use of non-coplanar beams and has significant potential to achieve better plan quality in radiation therapy.
منابع مشابه
Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison
Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...
متن کاملDosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma
Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...
متن کاملOptimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کاملIs Single Arc Technique in Volumetric Modulated Arc Therapy Good Enough for Prostate Cancer?
Advancement in treatment delivery techniques in external beam radiation therapy has significantly improved the conformal radiation dose distributions to the tumor while reducing dose to the critical structures. Modern treatment techniques combined with sophisticated treatment planning systems have led to increase in the treatment planning studies in the recent years. In this article, we review ...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008