Automated blood-sample handling in the clinical laboratory.
نویسندگان
چکیده
The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.
منابع مشابه
Aberration of Erythrocyte Sedimentation Rate by Zinc Nanoparticles
Dear Editor, erythrocyte sedimentation rate (ESR) is a useful basic clinical pathology laboratory investigation. It can be helpful in diagnosis and follow-up of several diseases. At present, a new automated method with proven reliability is available for ESR test (1). Here, the authors report on observation on a laboratory experiment to test the effect of zinc nanoparticles on ESR results. The...
متن کاملEffects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer
To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...
متن کاملLaboratory evaluation of the Glucocard blood glucose test meter.
The Glucocard (Kyoto Daiichi Kagaku) blood glucose meter is designed for self-monitoring of blood glucose concentrations in capillary blood through use of an electrochemical test strip. Evaluated in this laboratory, the Glucocard had CVs of 4.6%, 6.6%, and 3.5% at blood glucose concentrations of 2.4, 4.1, and 18.9 mmol/L, respectively. The meter's response varied linearly with blood glucose con...
متن کاملA kinetic spectrophotometric assay for rapid determination of acetoacetate in blood.
We describe an automated kinetic assay for acetoacetate in blood. Acetoacetate is enzymatically reduced to D-beta-hydroxybutyrate and the reaction is monitored for 60 s with a reaction-rate analyzer. This technique allows low concentrations of acetoacetate to be measured with good precision and overcomes many of the problems associated with other automated techniques. Our studies on the stabili...
متن کاملThe RABiT: high-throughput technology for assessing global DSB repair.
At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have developed a rapid automated biodosimetry tool (RABiT); this is a completely automated, ultra-high-throughput robotically based biodosimetry workstation designed for use following a large-scale radiological event, to perform radiation biodosimetry measurements based on a fingerstick blood sample. High throughput...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 36 9 شماره
صفحات -
تاریخ انتشار 1990