Comparison of Vascular Responses Following New‐Generation Biodegradable and Durable Polymer‐Based Drug‐Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model
نویسندگان
چکیده
BACKGROUND Incomplete endothelialization is the primary substrate of late stent thrombosis; however, recent reports have revealed that abnormal vascular responses are also responsible for the occurrence of late stent failure. The aim of the current study was to assess vascular response following deployment of biodegradable polymer-based Synergy (Boston Scientific) and Nobori (Terumo) drug-eluting stents and the durable polymer-based Resolute Integrity stent (Medtronic) in an atherosclerotic rabbit iliac artery model. METHODS AND RESULTS A total of 24 rabbits were fed an atherogenic diet, and then a balloon injury was used to induce atheroma formation. Synergy, Nobori, and Resolute Integrity stents were randomly implanted in iliac arteries. Animals were euthanized at 28 days for scanning electron microscopic evaluation and at 90 days for histological analysis. The percentage of uncovered strut area at 28 days was lowest with Synergy, followed by Resolute Integrity, and was significantly higher with Nobori stents (Synergy 1.1±2.2%, Resolute Integrity 2.0±3.9%, Nobori 4.6±3.0%; P<0.001). At 90 days, inflammation score was lowest for Synergy (0.27±0.45), followed by Nobori (0.62±0.59), and was highest for Resolute Integrity (0.89±0.46, P<0.001). Foamy macrophage infiltration within neointima (ie, neoatherosclerosis) was significantly less with Synergy (0.62±0.82) compared with Nobori (0.85±0.74) and Resolute Integrity (1.39±1.32; P=0.034). CONCLUSIONS The biodegradable polymer-coated thin-strut Synergy drug-eluting stent showed the fastest stent strut neointimal coverage and the lowest incidence of neoatherosclerosis in the current animal model.
منابع مشابه
Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: rationale and design of the BIOSCIENCE trial.
BACKGROUND Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) w...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کاملBaremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...
متن کاملVASCULAR BIOLOGY Original Studies In Vivo Comparison of a Polymer-Free Biolimus A9-Eluting Stent With a Biodegradable Polymer-Based Biolimus A9 Eluting Stent and a Bare Metal Stent in Balloon Denuded and Radiated Hypercholesterolemic Rabbit Iliac Arteries
Objectives: To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries. Methods: Rabbits were fed with 1% cholesterol diet (n 5 14) for 14 days, both iliac arteries ...
متن کاملFirst experimental application of bevacizumab-eluting PC coated stent for inhibition of vasa vasorum of atherosclerotic plaque: angiographic results in a rabbit atheromatic model.
INTRODUCTION Atheromatosis is associated with angiogenesis, through the development of a dense net of vasa vasorum. The role of vascular endothelial growth factor (VEGF) is important in this process. Bevacizumab, an antibody specific for VEGF, has recently been applied in the clinical field. We hypothesized that local delivery of bevacizumab by stent would inhibit the development of vasa vasoru...
متن کامل