Comparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan

نویسندگان

  • Wassia A Khaja
  • Sandeep Grover
  • Amy T Kelmenson
  • Lee R Ferguson
  • Kumar Sambhav
  • Kakarla V Chalam
چکیده

BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many studies have correlated the measurement of CCT with all four modalities. The purpose of this study was to compare and correlate the CCT measurements obtained by US pachymetry with SL-OCT, specular microscopy, and Orbscan. METHOD This is a prospective, comparative study done in an institutional setting. Thirty-two eyes of 32 subjects with no known ocular disease and best-corrected visual acuity of 20/20 were enrolled. CCT measurements were obtained using SL-OCT, specular microscopy, scanning slit topography (Orbscan), and US pachymetry. Three measurements were made with each instrument by the same operator. Mean, standard deviation, and coefficient of variation were calculated for CCT measurements acquired by the four measurement devices. Bland-Altman plot was constructed to determine the agreements between the CCT measurements obtained by different equipment. RESULTS The mean CCT was 548.16±48.68 μm by US pachymetry. In comparison, CCT averaged 546.36±44.17 μm by SL-OCT, 557.61±49.92 μm by specular microscopy, and 551.03±48.96 μm by Orbscan for all subjects. Measurements by the various modalities were strongly correlated. Correlations (r (2)) of CCT, as measured by US pachymetry compared with other modalities, were: SL-OCT (r (2)=0.98, P<0.0001), specular microscopy (r (2)=0.98, P<0.0001), and Orbscan (r (2)=0.96, P<0.0001). All modalities had a linear correlation with US pachymetry measurements. CONCLUSION In subjects with healthy corneas, SL-OCT, specular microscopy, and Orbscan (with correction factor) can be used interchangeably with US pachymetry in certain clinical settings. The four modalities showed significant linear correlations with one another.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis.

AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...

متن کامل

SCIENTIFIC REPORT Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis

Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...

متن کامل

Measurement of corneal swelling variations without removal of the contact lens during extended wear.

PURPOSE To validate the use of noncontact scanning slit pachymetry and OCT pachymetry measurements without contact lens (CL) removal, to determine corneal swelling variations during extended wear (EW). METHODS Central corneal thickness (CCT) was measured with ultrasonic (US) pachymetry, noncontact scanning slit pachymetry (Orbscan II; Bausch & Lomb, Tampa, FL), and optical coherence tomograph...

متن کامل

Viscoat versus Visthesia during phacoemulsification cataract surgery: corneal and foveal changes

BACKGROUND Ophthalmic viscosurgical devices (OVDs) are widely used in phacoemulsification cataract surgery to maintain adequate intraocular space, stabilize ocular tissue during the operation and decrease the possible damage of the corneal endothelium. Our study has the purpose to compare the corneal and foveal changes of Viscoat and Visthesia in patients undergoing uneventful phacoemulsificati...

متن کامل

Comparison of optical coherence reflectometry and ultrasound central corneal pachymetry.

In 50 eyes of 25 patients we prospectively measured the central corneal thickness (CCT) comparing the OLCR (Optical Low Coherence Reflectometry) pachymeter with the contact ultrasound pachymeter. The OLCR system was mounted on to a Haag-Streit slit lamp. Every single measurement was the result of 5 scans. With the contact ultrasound Sonomed pachymeter we performed 5 separate measurements and ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015