Determination of SCN- in urine and saliva of smokers and non-smokers by SCN(-)-selective polymeric membrane containing a nickel(II)-azamacrocycle complex coated on a graphite electrode.

نویسندگان

  • Mohammad Reza Ganjali
  • Mohammad Yousefi
  • Mehran Javanbakht
  • Tahereh Poursaberi
  • Masoud Salavati-Niasari
  • Leila Hajiagha-Babaei
  • Elnaz Latifi
  • Mojtaba Shamsipur
چکیده

The construction, performance characteristics, and application of a novel polymeric membrane coated on a graphite electrode with unique selectivity towards SCN- are reported. The electrode was prepared by incorporating Ni(II)-2,2,4,9,9,11-hexamethyltetraazacyclotetradecanediene perchlorate into a plasticized poly(vinyl chloride) membrane. The influences of membrane composition, pH and foreign ions were investigated. The electrode displays a near Nernstian slope (-57.8 mV decade-1) over a wide concentration range of 1 x 10(-7)-1 x 10(-1) M of SCN- ion. The electrode has a detection limit of 4.8 x 10(-8) M (2.8 ng/cm3) SCN- and shows response times of about 15 s and 120 s for low to high and high to low concentration sequences, respectively. The proposed sensor shows high selectivity towards SCN- over several common organic and inorganic anions. The electrode revealed a great enhancement in selectivity coefficients and detection limit for SCN-, in comparison with the previously reported electrodes. It was successfully applied to the direct determination of SCN- in milk and biological samples, and as an indicator electrode in titration of Ag+ ions with thiocyanate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier

Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC...

متن کامل

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

متن کامل

Thiocyanate ion-selective PVC membrane electrode based on N,N'-ethylene-bis(4-methylsalicylidineiminato)nickel(II).

A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a goo...

متن کامل

Determination of Mn2+ in Pharmaceutical Supplements by a Novel Coated Graphite Electrode Based on Zolpidem as a Neutral Ion Carrier

Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 18 8  شماره 

صفحات  -

تاریخ انتشار 2002