Load sensing surgical instruments.
نویسندگان
چکیده
Force and pressure sensing technology applied to smart surgical instruments as well as implants allow to give a direct feedback of loads to the surgeon lead to better reliability and success of surgical operations. A common technology used for sensors is low-cost piezoresistive thick-film technology. However, the standard thick-film firing conditions degrade the properties of medical alloys. In order to avoid this problem, the solution is to decrease the firing temperature of thick films. This work presents the development and characterisation of low-firing thick-film systems (dielectrics, resistors and conductors), formulated to achieve chemical and thermal expansion compatibility with an austenitic stainless steel medical alloy. Adherence tests and results on electrical properties of these systems: resistance, temperature coefficient of resistance (TCR) are presented. It was found that the main issue in these systems lies in mastering the materials interactions during firing, especially at the silver-based resistor terminations. The interaction of silver, resistor and dielectric tends to give rise to highly resistive zones at the terminations, affecting reliability. This can be circumvented by post-firing the resistor terminations at a moderate temperature.
منابع مشابه
Intra-operative Ischemia Sensing Surgical Instruments
Surgical techniques rely heavily on adequate visualization of target anatomy. Particularly in laparoscopic and robotic laparoscopic surgery, the operative anatomy and the general view of the operative field is removed from the surgeon’s direct vision. Manipulation of peripheral anatomy (i.e. retraction) may lead to ischemia, infarction, and mechanical disruption. The primary goal of our researc...
متن کاملA soft pop-up proprioceptive actuator for minimally invasive surgery
INTRODUCTION Surgical robots and miniaturized smart instruments have been developed to overcome limitations of current tools and further reduce invasiveness of surgical procedures [1][2]. This miniaturization effort, as well as the development of more flexible instruments that can navigate the body following complex anatomical paths toward the surgical target, often leads to the loss of sensory...
متن کاملGroup 5 Project Proposal Prototype of a Micro-Surgical Tool Tracker
Computer and robot assisted eye surgery has great potential to address common problems encountered in many eye surgery tasks including poor visualization, lack of force sensing, hand tremor, and accessibility. Positional feedback of the instruments relative to the eye can be used to prevent undesirable collisions, improve remote center of motion interaction, and possibly automate tasks like ins...
متن کاملStrain and Damage Sensing Property of Self-compacting Concrete Reinforced with Carbon Fibers
Present paper investigated the strain and damage sensing property on concrete cubes embedded with carbon fibers. Concrete cubes of dimension 150 mm have been casted with different concentration of carbon fibers to study the strain and damage sensing property under cyclic loading that can be further used for health monitoring as non-destructive testing (NDT) approach. All the specimens were test...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of materials science. Materials in medicine
دوره 20 Suppl 1 شماره
صفحات -
تاریخ انتشار 2009